Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/04/09 12:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,26 +6,14 @@ 6 6 7 7 === Discrete inputs === 8 8 9 -The BMS Main X device has 4 discrete inputs of the "dry contact" type. For each discrete input, its assignment and inversion flag are set. 9 +The BMS Main X device has **4 discrete inputs** of the "dry contact" type. For each discrete input, its assignment and inversion flag are set. 10 10 11 11 Assignments of discrete inputs are configured in the "Signals - Input discrete signals - Assignments" section: 12 12 13 13 [[image:1734356322695-445.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="600"]] 14 14 15 - Thedevice supportsthefollowingdiscrete inputsassignments:15 +A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 16 16 17 -* No input – input is not used; 18 -* Battery cover – a signal from the battery cover; 19 -* Charge request – a request to close the main charging contactor; 20 -* Precharge request – a request to close the main precharging contactor; 21 -* Discharge request – a request to close the main discharging contactor; 22 -* Charging contactor feedback – a feedback signal from the charging contactor; 23 -* Discharging contactor feedback – a feedback signal from the discharging contactor; 24 -* Charging/Discharging contactor feedback – a feedback signal from the charging/discharging contactor; 25 -* Insulation status – a signal from an insulation monitoring device; 26 -* Join to charge – a request to join (connect in parallel) battery modules to charge the battery; 27 -* Join to discharge – a request to join (connect in parallel) battery modules to discharge the battery. 28 - 29 29 Inversion flags for discrete inputs are configured in the "Signals - Input discrete signals - Inversion" section: 30 30 31 31 [[image:1734356322698-182.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="600"]] ... ... @@ -32,7 +32,7 @@ 32 32 33 33 === Discrete outputs === 34 34 35 -The BMS Main X device has 4 +5Vdigital outputs. For each discrete output, its assignment and inversion flag are set.23 +The BMS Main X device has **4 digital outputs**. For each discrete output, its assignment and inversion flag are set. 36 36 37 37 Assignments of discrete outputs are configured in the "Signals - Output discrete signals - Assignments" section: 38 38 ... ... @@ -49,7 +49,7 @@ 49 49 50 50 === Relays === 51 51 52 -The BMS Main X device has 3 opto-relays for controlling main contactors. For each opto-relay, its assignment and inversion flag are set. 40 +The BMS Main X device has **3 opto-relays** for controlling main contactors. For each opto-relay, its assignment and inversion flag are set. 53 53 54 54 Assignments of relays are configured in the "Signals - Relays - Assignments" section: 55 55