3.2 Inputs and outputs

Version 1.3 by Admin on 2025/02/28 12:51

Configuration

Inputs and outputs

Discrete inputs

The BMS Main X device has 4 discrete inputs of the "dry contact" type. For each discrete input, its assignment and inversion flag are set.

Assignments of discrete inputs are configured in the "Signals - Input discrete signals - Assignments" section:

1734356322695-445.png

A list of available discrete input assignments is available in Input signals.

Inversion flags for discrete inputs are configured in the "Signals - Input discrete signals - Inversion" section:

1734356322698-182.png

Discrete outputs

The BMS Main X device has 4 digital outputs. For each discrete output, its assignment and inversion flag are set.

Assignments of discrete outputs are configured in the "Signals - Output discrete signals - Assignments" section:

1734356322699-904.png

The device supports the following digital output assignments:

  • No output – output is not used.

Inversion flags for discrete outputs are configured in the "Signals - Output discrete signals - Inversion" section:

1734356322700-310.png

Relays

The BMS Main X device has 3 opto-relays for controlling main contactors. For each opto-relay, its assignment and inversion flag are set.

Assignments of relays are configured in the "Signals - Relays - Assignments" section:

1734356322702-918.png

The device supports the following relay assignments:

  • No relay – relay is not used;
  • Charging – main charging contactor;
  • Precharging – main precharging contactor;
  • Discharging – main discharging contactor;
  • Charging/Discharging – main charging/discharging contactor.

Inversion flags for relays are configured in the “Signals – Relays – Inversion” section:

1734356322702-133.png