Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -60,8 +60,10 @@ 60 60 61 61 To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section: 62 62 63 -[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]] In this section:63 +[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]] 64 64 65 +In this section: 66 + 65 65 * Enable – a flag to enable communication with the IMD; 66 66 * CAN port – port which is used to communicate with the IMD: 67 67 ** CAN1 (ext); ... ... @@ -76,8 +76,10 @@ 76 76 77 77 To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 78 78 79 -[[image:1739294567774-840.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="600"]] In this section:81 +[[image:1739294567774-840.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="600"]] 80 80 83 +In this section: 84 + 81 81 * Enable – a flag to enable communication with the vehicle; 82 82 * CAN port – port which is used to communicate with the vehicle; 83 83 * Use CRC – a flag to enable checking the checksum of the control message; ... ... @@ -107,27 +107,3 @@ 107 107 * Version: Serial Number; 108 108 * Version: Production date; 109 109 * Errors 1, 2 for emergency shutdown – a bitfield with errors to emergency shutdown the vehicle. 110 - 111 -=== ATIB charger === 112 - 113 -To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → ATIB charger" section: 114 -[[image:1739294769684-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="600"]] 115 - 116 -In this section: 117 - 118 -* Enable – a flag to enable communication with the charger; 119 -* CAN port – port which is used to communicate with the charger: 120 -** CAN1 (ext); 121 -** CAN2 (int); 122 -* Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond; 123 -* Output period - a period of sending commands to the charger, millisecond; 124 -* Charging voltage – maximum charging voltage, V; 125 -* Charging current – maximum charging current, A; 126 -* Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established. 127 - 128 -(% class="box infomessage" %) 129 -((( 130 -After changing the settings, restart the BMS Main 3X device. 131 -))) 132 - 133 -
- 1739294769684-405.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.5 KB - Content