... ... @@ -1,51 +1,0 @@
1 -(% class="box infomessage" %)
2 -(((
3 -BMS Main X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main X.5\. Firmware update.WebHome]].
4 -)))
5 -
6 -= v2.6.3 =
7 -
8 -[[BMS_Main_X2_v2.6.3.srec>>FileManager.BMS_Main_X2_v2\.6\.3\.srec]]
9 -
10 -== Improvements ==
11 -
12 -* adaptation of the device to the production test bench
13 -
14 -= v2.6.2 =
15 -
16 -[[BMS_Main_X2_v2.6.2.srec>>FileManager.BMS_Main_X2_v2\.6\.2\.srec]]
17 -
18 -== Fixes ==
19 -
20 -* resolving the problem of saving device parameters
21 -
22 -= v2.6.1 =
23 -
24 -[[BMS_Main_X2_v2.6.1.srec>>FileManager.BMS_Main_X2_v2\.6\.1\.srec]]
25 -
26 -== Fixes ==
27 -
28 -* resolving the issue of preparing battery module states written to Modbus registers
29 -* resolving the problem of writing the device's working time to a non-volatile memory very often
30 -* resolving the problem of returning error states when saving device parameters (mainly via Wi-Fi)
31 -
32 -= v2.6.0 =
33 -
34 -[[BMS_Main_X2_v2.6.0.srec>>FileManager.BMS_Main_X2_v2\.6\.0\.srec]]
35 -
36 -== Features ==
37 -
38 -* new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections)
39 -* ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections)
40 -* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Heater", "Control - Cooler" sections)
41 -* new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules
42 -* new assignments "Charging", "Precharging", "Discharging", "Charging/Discharging", "Main contactor", "Critical error" and "General error (modules)" for the discrete outputs (see the "Signals - Output discrete signals - Assignments" section)
43 -* new assignments "Critical error" and "General error (modules)" for the relays (see the "Signals - Relays - Assignments" section)
44 -
45 -== Improvements ==
46 -
47 -* rearrangements in the settings sections, which are made to simplify the setup process
48 -
49 -== Fixes ==
50 -
51 -* resolving the problem of device hanging due to high activity on the CAN bus during startup