Changes for page BMS Main X
Last modified by Admin on 2025/02/19 08:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,0 +1,51 @@ 1 +(% class="box infomessage" %) 2 +((( 3 +BMS Main X firmware update procedure is described [[here>>doc:Battery management systems.BMS Main X.5\. Firmware update.WebHome]]. 4 +))) 5 + 6 += v2.6.3 = 7 + 8 +[[BMS_Main_X2_v2.6.3.srec>>FileManager.BMS_Main_X2_v2\.6\.3\.srec]] 9 + 10 +== Improvements == 11 + 12 +* adaptation of the device to the production test bench 13 + 14 += v2.6.2 = 15 + 16 +[[BMS_Main_X2_v2.6.2.srec>>FileManager.BMS_Main_X2_v2\.6\.2\.srec]] 17 + 18 +== Fixes == 19 + 20 +* resolving the problem of saving device parameters 21 + 22 += v2.6.1 = 23 + 24 +[[BMS_Main_X2_v2.6.1.srec>>FileManager.BMS_Main_X2_v2\.6\.1\.srec]] 25 + 26 +== Fixes == 27 + 28 +* resolving the issue of preparing battery module states written to Modbus registers 29 +* resolving the problem of writing the device's working time to a non-volatile memory very often 30 +* resolving the problem of returning error states when saving device parameters (mainly via Wi-Fi) 31 + 32 += v2.6.0 = 33 + 34 +[[BMS_Main_X2_v2.6.0.srec>>FileManager.BMS_Main_X2_v2\.6\.0\.srec]] 35 + 36 +== Features == 37 + 38 +* new parameter to set the minimum number of battery modules allowed to join (see the "Control - Charge" and "Control - Discharge" sections) 39 +* ability to rejoin battery modules if their voltage is close to the battery voltage (see the "Control - Charge" and "Control - Discharge" sections) 40 +* selection of errors that cause reset of contactor control signals (see the "Control - Main contactor", "Control - Charge", "Control - Discharge", "Control - Heater", "Control - Cooler" sections) 41 +* new internal signal "General error (modules)" which is the logical sum of the "General error" signals from the battery modules 42 +* new assignments "Charging", "Precharging", "Discharging", "Charging/Discharging", "Main contactor", "Critical error" and "General error (modules)" for the discrete outputs (see the "Signals - Output discrete signals - Assignments" section) 43 +* new assignments "Critical error" and "General error (modules)" for the relays (see the "Signals - Relays - Assignments" section) 44 + 45 +== Improvements == 46 + 47 +* rearrangements in the settings sections, which are made to simplify the setup process 48 + 49 +== Fixes == 50 + 51 +* resolving the problem of device hanging due to high activity on the CAN bus during startup