Wiki source code of BMS Main 2R
Last modified by Admin on 2026/09/14 06:06
Show last authors
| author | version | line-number | content |
|---|---|---|---|
| 1 | (% class="box infomessage" %) | ||
| 2 | ((( | ||
| 3 | BMS Main 2R firmware update procedure is described [[here>>https://docs.movicomelectric.com/bin/view/Battery%20management%20systems/BMS%20Main%202R/6.%20Firmware%20update/]]. | ||
| 4 | ))) | ||
| 5 | |||
| 6 | = v2.11.0 = | ||
| 7 | |||
| 8 | [[BMS_Main_2R_v2.11.0.bin>>FileManager.BMS_Main_2R_v2\.11\.0\.bin]] | ||
| 9 | |||
| 10 | == Features == | ||
| 11 | |||
| 12 | * support for the BIT vehicle communication protocol | ||
| 13 | |||
| 14 | == Fixes == | ||
| 15 | |||
| 16 | * resolving the issue where the device may hang when encountering communication issues while sending a compressed answer via the CLI | ||
| 17 | |||
| 18 | = v2.10.2 = | ||
| 19 | |||
| 20 | [[BMS_Main_2R_v2.10.2.bin>>FileManager.BMS_Main_2R_v2\.10\.2\.bin]] | ||
| 21 | |||
| 22 | == Fixes == | ||
| 23 | |||
| 24 | * resolving the problem of device stability when reading/writing large amounts of data using the Modbus protocol | ||
| 25 | * resolving a problem in the cellular communications subsystem | ||
| 26 | * BMS Main 2R: removed unusable parameters from the "Control - Power down" and "Protections - Stuck contactor" sections | ||
| 27 | |||
| 28 | = v2.10.1 = | ||
| 29 | |||
| 30 | [[BMS_Main_2R_v2.10.1.bin>>FileManager.BMS_Main_2R_v2\.10\.1\.bin]] | ||
| 31 | |||
| 32 | == Improvements == | ||
| 33 | |||
| 34 | * support for multiple clients expecting compressed CLI responses | ||
| 35 | * deleting old log files when the SD card is full (see the corresponding flag in the "Service - SD card" section) | ||
| 36 | * renaming CAN1 to internal and CAN2 to external for BMS Main 2R | ||