Wiki source code of Connecting BMS Mini S / BMS Mini
Last modified by Admin on 2024/12/23 16:06
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | = Introduction = | ||
2 | |||
3 | This document describes how to connect the BMS Mini 2 and BMS Mini S to the BatteryCloud monitoring service. | ||
4 | |||
5 | Connecting the BMS Mini device to the BatteryCloud is performed in the following two steps: | ||
6 | |||
7 | * binding the BMS Mini to the BatteryCloud; | ||
8 | * configuring the BMS Mini for sending log files to the BatteryCloud. | ||
9 | |||
10 | = Binding BMS Mini to BatteryCloud = | ||
11 | |||
12 | ~1. Sign in to the BatteryCloud ([[https:~~/~~/cloud.movicomelectric.com/login>>url:https://cloud.movicomelectric.com/login]]). If you are not registered, please request access by emailing [[electric@movicom.com>>mailto:electric@movicom.com]] or [[cloud@movicomelectric.com>>mailto:cloud@movicomelectric.com]]. | ||
13 | |||
14 | [[image:1733917039346-393.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="228" width="300"]] | ||
15 | |||
16 | 2. Go to the “Resources – Systems” page. Click the Add” button, enter your unique BMS Mini key (keys are delivered upon request), and then click the “Add” button. If the entered key is correct a new system will be created. | ||
17 | |||
18 | [[image:1733917039349-209.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="300"]] | ||
19 | |||
20 | [[image:1733917039350-171.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="300"]] | ||
21 | |||
22 | [[image:1733917039351-375.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="142" width="300"]] | ||
23 | |||
24 | 1. Go to the “Resources – Batteries”. Click the “Create” button, enter a battery name, and then click the “Create” button. A new battery will be created. | ||
25 | |||
26 | [[image:1733917039352-662.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="300"]] | ||
27 | |||
28 | [[image:1733917039353-223.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="300"]] | ||
29 | |||
30 | [[image:1733917039354-981.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="300"]] | ||
31 | |||
32 | 3. Open the settings of the created battery by clicking on its name in the table on the “Resources – Batteries” page. | ||
33 | |||
34 | 4. Click the “Systems” tab and then the “Mount system” button. In the popped-up window, select the system type “BMS Mini” or “BMS Mini S”, the system which is installed in the battery (the “System S/N” field), and set the “Mounting date” (the mounting date is a date from which the cloud will display battery parameters). | ||
35 | |||
36 | [[image:1733917039354-590.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="191" width="600"]] | ||
37 | |||
38 | [[image:1733917039356-868.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="181" width="300"]] | ||
39 | |||
40 | From this moment, the BatteryCloud will be ready to show the battery data from the configured mounting date. | ||
41 | |||
42 | = Configuring BMS Mini to send log files = | ||
43 | |||
44 | ~1. Go to the “Service – SD-card” section and set the following parameters: | ||
45 | |||
46 | |**Parameter**|**Value** | ||
47 | |Enable|Yes | ||
48 | |Logging period, second|30 | ||
49 | |**Save logs with cell parameters**|No | ||
50 | |||
51 | [[image:1733917039357-908.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]] | ||
52 | |||
53 | 2. Go to the “Connectivity – Wi-Fi” section and set up the Wi-Fi connection which has access to the Internet. | ||
54 | |||
55 | 3. Go to the “Service – FTP” section and set the following connection parameters: | ||
56 | |||
57 | |**Parameter**|**Value** | ||
58 | |Host|cloud.movicomelectric.com | ||
59 | |Port|21 | ||
60 | |User|bms | ||
61 | |Password|bms | ||
62 | |Sending period, second|120 | ||
63 | |**Send logs with cell parameters**|No | ||