Wiki source code of 1. Technical specifications

Version 2.2 by Admin on 2024/12/13 16:52

Show last authors
1 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Technical specifications =
3
4 [[image:1734108445189-173.png||data-xwiki-image-style-alignment="center"]]
5
6 BMS USB-RS485 1.x interface adapter provides conversion of USB bus signals to RS-485 bus signals. After connection to a PC device is recognized as a virtual COM port.
7
8 Adapter includes a switch to connect a 120 Ohm terminal resistor to RS-485 lines.
9
10 Device is compatible with the following operating systems: Windows 98, Windows ME, Windows 2000, Windows XP, Windows Vista, Windows 7, Windows 8/8.1, Windows 10, Mac OS 8/9, Mac OS X, Linux 2.4 and above.
11
12 The BMS USB-RS485 1.x interface adapter performs the following functions:
13
14 * conversion of USB interface signals to a two-wire trunk RS-485 interface signals with galvanic isolation (Vrms = 1000V);
15 * power supply and information exchange with BMS Logic devices using the ElectricDeviceMonitor software.
16
17 == Specifications ==
18
19 |**Parameter**|**Value**
20 |Supply voltage, V|5 (USB port)
21 |Current consumption without external load, mA (max)|80
22 |Maximum current consumption, mA|600
23 |Maximum output current via 5V line, mA|400
24 |RS-485 bus speed, bit/s|600, 1200, 2400, 4800,
25 9600, 19200, 38400, 57600, 115200
26 |RS-485 bus speed for communication with BMS Logic, bit/s|115200
27 |Dimensions (length × width × height), mm|91 × 50 × 27
28 |Weight, g|70
29 |(% colspan="2" %)**Operating conditions**
30 |Operating temperature range, ° С|-40÷75
31 |Degree of protection from external influences|IP20
32
33 == Connection diagrams ==
34
35 How to use the BMS USB-RS485 1.x adapter is described in the «BMS 2.1 – Connection manual».
36
37 Figure below shows a diagram of connecting a BMS Logic device to a PC using the BMS USB-RS485 1.x.
38
39 [[image:1734108445190-152.png||data-xwiki-image-style-alignment="center" height="373" width="300"]]
40
41 Next figure shows an option to connect the BMS USB-RS485 1.x to the RS-485 bus, which already integrates several devices. If the BMS USB-RS485 1.x is the last device on the bus, the 120 Ohm switch must be set to position "1".