Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -274,38 +274,38 @@ 274 274 275 275 To change the parameters of the main contactor, select the "Control → Main contactor" section: 276 276 277 -[[image:1777563933065-421.png]] 277 +[[image:1777563933065-421.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="800"]] 278 278 279 279 In this section: 280 280 281 -* Enable – a flag to enable the main contactor control; 282 -* Algorithm – main contactor control algorithm:283 -** Always on – contactor is always closed;284 -** Automatic – contactor closes by internal charge and discharge algorithms;285 -** On demand – contactor is closed by an external request;286 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed;287 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s;288 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset;289 -* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor.281 +* **Enable **– a flag to enable the main contactor control; 282 +* **Algorithm** – main contactor control algorithm: 283 +** **Always on** – contactor is always closed; 284 +** **Automatic** – contactor closes by internal charge and discharge algorithms; 285 +** **On demand** – contactor is closed by an external request; 286 +* **Time to keep the contactor closed before closing the others** – a time for other contactors to be open after the main contactor is closed; 287 +* **Delay before opening the contactor** – a time which is used to detect conditions for opening the contactor, s; 288 +* **Keep the contactor open until the device is restarted** – a flag for keeping the main contactor open until the system is reset; 289 +* **Errors 1, 2 to open the main contactor** – bitfields to choose the errors which will open the main contactor. 290 290 291 291 === Charging status === 292 292 293 293 To change the parameters of charging process status, select the "Control → Charging status" section: 294 294 295 - [[image:1762774819522-147.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="140" width="800"]]295 + 296 296 In this section: 297 297 298 -* Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 299 -* Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A;300 -* Use actual voltage togeneratethe"Ready to charge" signal– aflagto disable voltagecorrectionfor"Ready to charge"signal;301 -* Use actual voltage togeneratethe"Ready to charge"signalifthe current isnegative–aflagtodisable voltagecorrectionfor"Ready to charge"signalonly atdischargingcurrent;302 -* Voltage toclear the“Ready to charge”– athresholdU,,ocv,, (corrected due tocurrent andcell resistance)voltagelevelon thecell, V; ifthe voltage of anycell is abovethis level, the “Ready to charge”(hence, the “Allow charging”)signalis cleared;303 -* Voltage toreset the “Readytocharge” –atolerantU,,ocv,, (correcteddueto currentandcell resistance)voltagelevelonthecell,V;if all cellvoltagesarebelowthe tolerantlevel, the “Ready to charge”(hence,the“Allowcharging”)signal is set;304 -* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;305 -* Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal;306 -* Charge current limit to clear the 'Ready to charge' – a threshold charging current limit value, A; if the limit is//above //this level, the “Ready to charge” signal is cleared;307 -* Charge current limit to set the 'Ready to charge' – a tolerant charging current limit value, A; if the limit is//below //this level, the “Ready to charge” signal is set;308 -* Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal.298 +* **Current to set the "Charging current present"** – a current level to generate the "Charging current present" signal, A; 299 +* **Current to clear the "Charging current present"** – a current level to clear the "Charging current present" signal, A; 300 +* **Voltage to clear the “Ready to charge”** – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 301 +* **Voltage to reset the “Ready to charge”** – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 302 +* **Use actual voltage to generate the "Ready to charge" signal** – a flag to disable voltage correction for "Ready to charge" signal; 303 +* **Treat negative currents as zero currents for generating the "Ready to charge" signal** – a flag to disable voltage correction for "Ready to charge" signal at discharging current; 304 +* **Delay before recharging** – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 305 +* **Check the 'Charge current limit' value to generate the 'Ready to charge'** – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal; 306 +* **Charge current limit to clear the 'Ready to charge'** – a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” signal is cleared; 307 +* **Charge current limit to set the 'Ready to charge'** – a tolerant charging current limit value, A; if the limit is //below //this level, the “Ready to charge” signal is set; 308 +* **Errors 1, 2 to clear the "Ready to charge"** – bitfields to choose the errors which will clear the "Ready to charge" signal. 309 309 310 310 (% class="box infomessage" %) 311 311 (((
- 1777564033994-545.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.5 KB - Content