Changes for page 3.3 Control

Last modified by Admin on 2026/04/30 15:58

From version 56.2
edited by Admin
on 2026/04/30 15:45
Change comment: There is no comment for this version
To version 57.1
edited by Admin
on 2026/04/30 15:47
Change comment: Uploaded new attachment "1777564033994-545.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -274,38 +274,38 @@
274 274  
275 275  To change the parameters of the main contactor, select the "Control → Main contactor" section:
276 276  
277 -[[image:1777563933065-421.png]]
277 +[[image:1777563933065-421.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="800"]]
278 278  
279 279  In this section:
280 280  
281 -* Enable – a flag to enable the main contactor control;
282 -* Algorithm – main contactor control algorithm:
283 -** Always on – contactor is always closed;
284 -** Automatic – contactor closes by internal charge and discharge algorithms;
285 -** On demand – contactor is closed by an external request;
286 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed;
287 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s;
288 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset;
289 -* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor.
281 +* **Enable **– a flag to enable the main contactor control;
282 +* **Algorithm** – main contactor control algorithm:
283 +** **Always on** – contactor is always closed;
284 +** **Automatic** – contactor closes by internal charge and discharge algorithms;
285 +** **On demand** – contactor is closed by an external request;
286 +* **Time to keep the contactor closed before closing the others** – a time for other contactors to be open after the main contactor is closed;
287 +* **Delay before opening the contactor** – a time which is used to detect conditions for opening the contactor, s;
288 +* **Keep the contactor open until the device is restarted** – a flag for keeping the main contactor open until the system is reset;
289 +* **Errors 1, 2 to open the main contactor** – bitfields to choose the errors which will open the main contactor.
290 290  
291 291  === Charging status ===
292 292  
293 293  To change the parameters of charging process status, select the "Control → Charging status" section:
294 294  
295 -[[image:1762774819522-147.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="140" width="800"]]
295 +
296 296  In this section:
297 297  
298 -* Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A;
299 -* Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A;
300 -* Use actual voltage to generate the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal;
301 -* Use actual voltage to generate the "Ready to charge" signal if the current is negative a flag to disable voltage correction for "Ready to charge" signal only at discharging current;
302 -* Voltage to clear the Ready to charge – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge (hence, the “Allow charging”) signal is cleared;
303 -* Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge (hence, the “Allow charging”) signal is set;
304 -* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
305 -* Check the 'Charge current limit' value to generate the 'Ready to charge' – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal;
306 -* Charge current limit to clear the 'Ready to charge' – a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” signal is cleared;
307 -* Charge current limit to set the 'Ready to charge' – a tolerant charging current limit value, A; if the limit is //below //this level, the “Ready to charge” signal is set;
308 -* Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal.
298 +* **Current to set the "Charging current present"** – a current level to generate the "Charging current present" signal, A;
299 +* **Current to clear the "Charging current present"** – a current level to clear the "Charging current present" signal, A;
300 +* **Voltage to clear the Ready to charge”** – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge (hence, the “Allow charging”) signal is cleared;
301 +* **Voltage to reset the Ready to charge”** – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge (hence, the “Allow charging”) signal is set;
302 +* **Use actual voltage to generate the "Ready to charge" signal** – a flag to disable voltage correction for "Ready to charge" signal;
303 +* **Treat negative currents as zero currents for generating the "Ready to charge" signal** – a flag to disable voltage correction for "Ready to charge" signal at discharging current;
304 +* **Delay before recharging** – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0;
305 +* **Check the 'Charge current limit' value to generate the 'Ready to charge'** – a flag to enable check of "Charging current limit" to generate the "Ready to charge" signal;
306 +* **Charge current limit to clear the 'Ready to charge'** – a threshold charging current limit value, A; if the limit is //above //this level, the “Ready to charge” signal is cleared;
307 +* **Charge current limit to set the 'Ready to charge'** – a tolerant charging current limit value, A; if the limit is //below //this level, the “Ready to charge” signal is set;
308 +* **Errors 1, 2 to clear the "Ready to charge"** – bitfields to choose the errors which will clear the "Ready to charge" signal.
309 309  
310 310  (% class="box infomessage" %)
311 311  (((
1777564033994-545.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +38.5 KB
Content