Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -144,6 +144,8 @@ 144 144 145 145 === Low SOC (signal) === 146 146 147 +The "Low SOC" is indicative signal that can be assigned to a discrete output or a power switch. 148 + 147 147 To change the parameters of the generation a signal about low battery level, select the "Control → Low SOC (signal)" section: 148 148 149 149 [[image:1740396460923-423.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]] ... ... @@ -165,13 +165,10 @@ 165 165 166 166 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 167 167 168 -(% class="box infomessage" %) 169 -((( 170 -The "Low SOC signal" is indicative and can be output to a discrete output or a power switch. 171 -))) 172 - 173 173 === High charging current (signal) === 174 174 172 +The "High charging current" is indicative signal that can be output to a discrete output or a power switch. 173 + 175 175 To change the parameters of the generation high-current signal, select the "Control → High charging current (signal)" section: 176 176 177 177 [[image:1740396996935-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]] ... ... @@ -178,12 +178,12 @@ 178 178 179 179 In this section: 180 180 181 -* Enable – a flag to enable signal generation;182 -* Maximum charging current, А; 183 -* Tolerant charging current, А; 184 -* Delay before setting the signal, second; 185 -* Delay before clearing the signal, second; 186 -* Lock – lock the signal until the device is reset. 180 +* **Enable **– a flag to enable signal generation; 181 +* **Maximum charging current**, А; 182 +* **Tolerant charging current**, А; 183 +* **Delay before setting the signal**, second; 184 +* **Delay before clearing the signal**, second; 185 +* **Lock **– lock the signal until the device is reset. 187 187 188 188 Signal generation conditions: 189 189 ... ... @@ -193,16 +193,11 @@ 193 193 194 194 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 195 195 196 -(% class="box infomessage" %) 197 -((( 198 -The "High charging current" signal is indicative and can be output to a discrete output or a power switch. 199 -))) 200 - 201 201 === Charge map === 202 202 203 203 The BMS Mini S / BMS Mini device calculates maximum allowable charge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. 204 204 205 -Calculated current values are sen dingto a charger or an intellectual load over the CAN bus.199 +Calculated current values are sent to a charger or an intellectual load over the CAN bus. External devices based on received data provide correct battery operation. 206 206 207 207 To configure parameters for determining the charge current limit, select the "Control → Charge map" section: 208 208 ... ... @@ -209,17 +209,17 @@ 209 209 [[image:1740397188247-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="800"]] 210 210 In this section: 211 211 212 -* Enable – a flag to start calculation of the charge current limit; 213 -* Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A;214 -* Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s;215 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs**depending on__maximum cell SOC__and battery temperature;216 -* Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature;217 -* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current**Kcc**depending on contactor temperature;218 -* Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature;219 -* Option 3: Limit charge current by the maximum cell voltage -a flag to enable correction of maximum allowable charging current**Kcv**depending on__the maximum cell U,,ocv,, voltage__ (corrected due to current and cell resistance)220 -* Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage;221 -* Option 4: Limit charge current by the cell temperature -a flag to enable correction of maximum allowable charging current**Kct**depending on maximum cell temperature;222 -* Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature.206 +* **Enable **– a flag to start calculation of the charge current limit; 207 +* **Maximum charge current** – a maximum allowable value of the charge current (under normal conditions), A; 208 +* **Rate of change** – a rate of change the current limit to a new value (0 is for immediate change), A/s; 209 +* **Option 1: Limit charge current by the battery SOC and temperature** – a flag to enable correction of maximum allowable charging current** Kcs** depending on __maximum cell SOC__ and battery temperature; 210 +* **Option 1: SOC x Temperature x Factor** – the dependence of the correction factor on SOC and battery temperature; 211 +* **Option 2: Limit charge current by the contactor temperature** – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature; 212 +* **Option 2: Contactor temperature x Factor** – the dependence of the correction factor on SOC and contactor temperature; 213 +* **Option 3: Limit charge current by the maximum cell voltage** – a flag to enable correction of maximum allowable charging current **Kcv** depending on __the maximum cell U,,ocv,, voltage__ (corrected due to current and cell resistance) 214 +* **Option 3: Cell voltage x Factor** – the dependence of the correction factor on maximum cell voltage; 215 +* **Option 4: Limit charge current by the cell temperature** – a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature; 216 +* **Option 4: Cell temperature x Factor** – the dependence of the correction factor on maximum cell temperature. 223 223 224 224 Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows: 225 225
- 1777563933065-421.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.1 KB - Content