Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,11 +12,11 @@ 12 12 13 13 In this section: 14 14 15 -* **Cell capacity**– nominal capacity of cells, Ah;16 -* **Cell resistance**– nominal (maximum) internal resistance of the cell, Ohm;17 -* **Relax time (after charging)**– a relaxation time after charging, second;18 -* **Relax time (after discharging)**– the relaxation time after discharging, second;19 -* **Reset parameters**– a command to reset cells state of charge, capacity, and resistance.15 +* Cell capacity – nominal capacity of cells, Ah; 16 +* Cell resistance – nominal (maximum) internal resistance of the cell, Ohm; 17 +* Relax time (after charging) – a relaxation time after charging, second; 18 +* Relax time (atfer discharging) – the relaxation time after discharging, second; 19 +* Reset parameters– a command to reset cells state of charge, capacity, and resistance. 20 20 21 21 The values “Capacity” and “Resistance” are used to calculate the SOC of cells and the battery. 22 22 ... ... @@ -334,7 +334,7 @@ 334 334 * Check the 'Discharge current limit' value to generate the 'Ready to discharge' – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal; 335 335 * Discharge current limit to clear the 'Ready to discharge' – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared; 336 336 * Discharge current limit to set the 'Ready to discharge' – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set; 337 -* Clear the 'Ready to discharge' signal if the 'Low SOC' signal is set;337 +* Clear the 'Ready to charge' signal if the 'Low SOC' signal is set – a 338 338 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 339 339 340 340 === Precharge === ... ... @@ -623,13 +623,13 @@ 623 623 624 624 To change the parameters of the heater control algorithm, select the "Control → Heater" section: 625 625 626 -[[image:1777293968000-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]] 626 + 627 +[[image:1740404973346-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 627 627 In this section: 628 628 629 629 * Enable – a flag to enable heater control; 630 630 * Minimum cell temperature, °C; 631 631 * Tolerant cell temperature, °C; 632 -* Start the heater only if "Charger connected" signal is set; 633 633 * Delay before starting the heater, millisecond; 634 634 * Delay before stopping the heater, millisecond; 635 635 * Errors 1, 2 to turn off the heater – bitfields to choose the errors which will turn off the heater.
- 1777293968000-235.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.5 KB - Content
- 1777294483990-350.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.5 KB - Content