Changes for page 3.3 Control
Last modified by Admin on 2026/04/30 15:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,13 +12,13 @@ 12 12 13 13 In this section: 14 14 15 -* Cell capacity – nominal capacity of cells, Ah; 16 -* Cell resistance – nominal (maximum) internal resistance of the cell, Ohm; 17 -* Relax time (after charging) – a relaxation time after charging, second; 18 -* Relax time (a tfer discharging) – the relaxation time after discharging, second;19 -* Reset parameters– a command to reset cells state of charge, capacity, and resistance. 15 +* **Cell capacity** – nominal capacity of cells, Ah; 16 +* **Cell resistance** – nominal (maximum) internal resistance of the cell, Ohm; 17 +* **Relax time (after charging)** – a relaxation time after charging, second; 18 +* **Relax time (after discharging)** – the relaxation time after discharging, second; 19 +* **Reset parameters **– a command to reset cells state of charge, capacity, and resistance. 20 20 21 -The values “Capacity” and “Resistance” are used to calculate the SOC of cells and the battery. 21 +The values “**Capacity**” and “**Resistance**” are used to calculate the SOC of cells and the battery. 22 22 23 23 The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery. 24 24 ... ... @@ -623,13 +623,13 @@ 623 623 624 624 To change the parameters of the heater control algorithm, select the "Control → Heater" section: 625 625 626 - 627 -[[image:1740404973346-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 626 +[[image:1777293968000-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]] 628 628 In this section: 629 629 630 630 * Enable – a flag to enable heater control; 631 631 * Minimum cell temperature, °C; 632 632 * Tolerant cell temperature, °C; 632 +* Start the heater only if "Charger connected" signal is set; 633 633 * Delay before starting the heater, millisecond; 634 634 * Delay before stopping the heater, millisecond; 635 635 * Errors 1, 2 to turn off the heater – bitfields to choose the errors which will turn off the heater.
- 1777294483990-350.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.5 KB - Content