Changes for page 3.3 Control

Last modified by Admin on 2026/04/30 15:58

From version 52.1
edited by Admin
on 2026/04/27 12:46
Change comment: Uploaded new attachment "1777293968000-235.png", version {1}
To version 54.2
edited by Admin
on 2026/04/30 12:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,11 +12,11 @@
12 12  
13 13  In this section:
14 14  
15 -* Cell capacity – nominal capacity of cells, Ah;
16 -* Cell resistance – nominal (maximum) internal resistance of the cell, Ohm;
17 -* Relax time (after charging) – a relaxation time after charging, second;
18 -* Relax time (atfer discharging) – the relaxation time after discharging, second;
19 -* Reset parameters– a command to reset cells state of charge, capacity, and resistance.
15 +* **Cell capacity** – nominal capacity of cells, Ah;
16 +* **Cell resistance** – nominal (maximum) internal resistance of the cell, Ohm;
17 +* **Relax time (after charging)** – a relaxation time after charging, second;
18 +* **Relax time (after discharging)** – the relaxation time after discharging, second;
19 +* **Reset parameters **– a command to reset cells state of charge, capacity, and resistance.
20 20  
21 21  The values “Capacity” and “Resistance” are used to calculate the SOC of cells and the battery.
22 22  
... ... @@ -623,13 +623,13 @@
623 623  
624 624  To change the parameters of the heater control algorithm, select the "Control → Heater" section:
625 625  
626 -
627 -[[image:1740404973346-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
626 +[[image:1777293968000-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]]
628 628  In this section:
629 629  
630 630  * Enable – a flag to enable heater control;
631 631  * Minimum cell temperature, °C;
632 632  * Tolerant cell temperature, °C;
632 +* Start the heater only if "Charger connected" signal is set;
633 633  * Delay before starting the heater, millisecond;
634 634  * Delay before stopping the heater, millisecond;
635 635  * Errors 1, 2 to turn off the heater – bitfields to choose the errors which will turn off the heater.
1777294483990-350.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content