... ... @@ -12,13 +12,13 @@
12 12  
13 13  In this section:
14 14  
15 -* Cell capacity – nominal capacity of cells, Ah;
16 -* Cell resistance – nominal (maximum) internal resistance of the cell, Ohm;
17 -* Relax time (after charging) – a relaxation time after charging, second;
18 -* Relax time (atfer discharging) – the relaxation time after discharging, second;
19 -* Reset parameters– a command to reset cells state of charge, capacity, and resistance.
15 +* **Cell capacity** – nominal capacity of cells, Ah;
16 +* **Cell resistance** – nominal (maximum) internal resistance of the cell, Ohm;
17 +* **Relax time (after charging)** – a relaxation time after charging, second;
18 +* **Relax time (after discharging)** – the relaxation time after discharging, second;
19 +* **Reset parameters **– a command to reset cells state of charge, capacity, and resistance.
20 20  
21 -The values “Capacity” and “Resistance” are used to calculate the SOC of cells and the battery.
21 +The values “**Capacity**” and “**Resistance**” are used to calculate the SOC of cells and the battery.
22 22  
23 23  The values of “Relax time” are used to determine the state of the battery. If the battery is in a state of relaxation, the system recalculates the voltage on the cells to the state of charge of the battery.
24 24  
... ... @@ -323,8 +323,7 @@
323 323  
324 324  To change the parameters of discharging process status, select the "Control → Discharging status" section:
325 325  
326 -[[image:1762774840204-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="146" width="800"]]
327 -In this section:
326 +[[image:1762774840204-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="146" width="800"]]In this section:
328 328  
329 329  * Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А;
330 330  * Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А;
... ... @@ -335,6 +335,7 @@
335 335  * Check the 'Discharge current limit' value to generate the 'Ready to discharge' – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal;
336 336  * Discharge current limit to clear the 'Ready to discharge' – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared;
337 337  * Discharge current limit to set the 'Ready to discharge' – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set;
337 +* Clear the 'Ready to discharge' signal if the 'Low SOC' signal is set;
338 338  * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal.
339 339  
340 340  === Precharge ===
... ... @@ -343,9 +343,11 @@
343 343  
344 344  BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. Also BMS can measure the power dissipated on precharge resistor and generate an error if it greater than configured limit.
345 345  
346 +To change the parameters of precharge contactor, select the "Control → Precharge" section:
347 +
346 346  [[image:1754931813173-804.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="172" width="800"]]
347 347  
348 -To change the parameters of precharge contactor, select the "Control → Precharge" section:
350 +In this section:
349 349  
350 350  * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A;
351 351  * Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay;
... ... @@ -621,13 +621,13 @@
621 621  
622 622  To change the parameters of the heater control algorithm, select the "Control → Heater" section:
623 623  
624 -
625 -[[image:1740404973346-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
626 +[[image:1777293968000-235.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]]
626 626  In this section:
627 627  
628 628  * Enable – a flag to enable heater control;
629 629  * Minimum cell temperature, °C;
630 630  * Tolerant cell temperature, °C;
632 +* Start the heater only if "Charger connected" signal is set;
631 631  * Delay before starting the heater, millisecond;
632 632  * Delay before stopping the heater, millisecond;
633 633  * Errors 1, 2 to turn off the heater – bitfields to choose the errors which will turn off the heater.
1769787007221-936.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +38.3 KB
Content
1777293968000-235.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content
1777294483990-350.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +25.5 KB
Content