... ... @@ -323,8 +323,7 @@ 323 323 324 324 To change the parameters of discharging process status, select the "Control → Discharging status" section: 325 325 326 -[[image:1762774840204-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="146" width="800"]] 327 -In this section: 326 +[[image:1762774840204-111.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="146" width="800"]]In this section: 328 328 329 329 * Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А; 330 330 * Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А; ... ... @@ -335,6 +335,7 @@ 335 335 * Check the 'Discharge current limit' value to generate the 'Ready to discharge' – a flag to enable check of "Discharging current limit" to generate the "Ready to discharge" signal; 336 336 * Discharge current limit to clear the 'Ready to discharge' – a threshold discharging current limit value, A; if the limit is //above //this level, the “Ready to discharge” signal is cleared; 337 337 * Discharge current limit to set the 'Ready to discharge' – a tolerant discharging current limit value, A; if the limit is //below //this level, the “Ready to discharge” signal is set; 337 +* Clear the 'Ready to charge' signal if the 'Low SOC' signal is set – a 338 338 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 339 339 340 340 === Precharge === ... ... @@ -343,9 +343,11 @@ 343 343 344 344 BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. Also BMS can measure the power dissipated on precharge resistor and generate an error if it greater than configured limit. 345 345 346 +To change the parameters of precharge contactor, select the "Control → Precharge" section: 347 + 346 346 [[image:1754931813173-804.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="172" width="800"]] 347 347 348 - To changethe parametersof precharge contactor,selectthe "Control → Precharge" section:350 +In this section: 349 349 350 350 * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A; 351 351 * Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay;
- 1769787007221-936.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.3 KB - Content