Changes for page 3.3 Control
Last modified by Admin on 2025/08/11 17:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -297,13 +297,11 @@ 297 297 298 298 To change the parameters of charging process status, select the "Control → Charging status" section: 299 299 300 -[[image:17 54931721385-562.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]300 +[[image:1740399071280-626.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 301 301 In this section: 302 302 303 303 * Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 304 304 * Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 305 -* Use actual voltage to generate the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal; 306 -* Use actual voltage to generate the "Ready to charge" signal if the current is negative – a flag to disable voltage correction for "Ready to charge" signal only at discharging current; 307 307 * Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 308 308 * Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 309 309 * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; ... ... @@ -320,13 +320,11 @@ 320 320 321 321 To change the parameters of discharging process status, select the "Control → Discharging status" section: 322 322 323 -[[image:17 54931699901-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="115" width="800"]]321 +[[image:1740399096018-240.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]] 324 324 In this section: 325 325 326 326 * Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А; 327 327 * Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А; 328 -* Use actual voltage to generate the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal; 329 -* Use actual voltage to generate the "Ready to discharge" signal if the current is positive – a flag to disable voltage correction for "Ready to discharge" signal only at charging current; 330 330 * Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 331 331 * Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 332 332 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. ... ... @@ -337,14 +337,12 @@ 337 337 338 338 BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. Also BMS can measure the power dissipated on precharge resistor and generate an error if it greater than configured limit. 339 339 340 -[[image:17 54931813173-804.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="172" width="800"]]336 +[[image:1740399150173-761.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="800"]] 341 341 342 342 To change the parameters of precharge contactor, select the "Control → Precharge" section: 343 343 344 344 * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A; 345 -* Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay; 346 346 * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 347 -* Delay before current measurement – a delay before first current measurement after closing precharge, millisecond; 348 348 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 349 349 * Relaxation between attempts – a duration between precharge attempts, millisecond; 350 350 * Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor;
- 1754931721385-562.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -31.7 KB - Content
- 1754931813173-804.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.8 KB - Content