... ... @@ -341,9 +341,10 @@
341 341  
342 342  To change the parameters of precharge contactor, select the "Control → Precharge" section:
343 343  
344 -* Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay;
345 345  * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A;
345 +* Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay;
346 346  * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error";
347 +* Delay before current measurement – a delay before first current measurement after closing precharge, millisecond;
347 347  * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;
348 348  * Relaxation between attempts – a duration between precharge attempts, millisecond;
349 349  * Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor;