... ... @@ -297,7 +297,7 @@
297 297  
298 298  To change the parameters of charging process status, select the "Control → Charging status" section:
299 299  
300 -[[image:1754931617275-503.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="135" width="800"]]
300 +[[image:1754931721385-562.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]
301 301  In this section:
302 302  
303 303  * Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A;
... ... @@ -320,11 +320,13 @@
320 320  
321 321  To change the parameters of discharging process status, select the "Control → Discharging status" section:
322 322  
323 -[[image:1754931699901-802.png]]
323 +[[image:1754931699901-802.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="115" width="800"]]
324 324  In this section:
325 325  
326 326  * Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А;
327 327  * Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А;
328 +* Use actual voltage to generate the "Ready to discharge" signal – a flag to disable voltage correction for "Ready to discharge" signal;
329 +* Use actual voltage to generate the "Ready to discharge" signal if the current is positive – a flag to disable voltage correction for "Ready to discharge" signal only at charging current;
328 328  * Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
329 329  * Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
330 330  * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal.
... ... @@ -335,12 +335,14 @@
335 335  
336 336  BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. Also BMS can measure the power dissipated on precharge resistor and generate an error if it greater than configured limit.
337 337  
338 -[[image:1740399150173-761.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="800"]]
340 +[[image:1754931813173-804.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="172" width="800"]]
339 339  
340 340  To change the parameters of precharge contactor, select the "Control → Precharge" section:
341 341  
342 342  * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A;
345 +* Keep the precharging relay closed until precharge is finished – a flag to ignore the Precharge time and wait precharging to finish before open precharge relay;
343 343  * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error";
347 +* Delay before current measurement – a delay before first current measurement after closing precharge, millisecond;
344 344  * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;
345 345  * Relaxation between attempts – a duration between precharge attempts, millisecond;
346 346  * Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor;