- Page properties
-
- Content
-
... ... @@ -208,11 +208,11 @@ 208 208 * Enable – a flag to start calculation of the charge current limit; 209 209 * Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A; 210 210 * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 211 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on __maximum cellSOC__and battery temperature;211 +* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on SOC and battery temperature; 212 212 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 213 213 * Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature; 214 214 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 215 -* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on __themaximum cellU,,ocv,, voltage__ (corrected due to current and cell resistance)215 +* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on maximum cell voltage; 216 216 * Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage; 217 217 * Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature; 218 218 * Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature. ... ... @@ -236,11 +236,11 @@ 236 236 * Enable – a flag to start calculation of the discharge current limit; 237 237 * Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions), A; 238 238 * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 239 -* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on __minimum cellSOC__and temperature;239 +* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on SOC and temperature; 240 240 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 241 241 * Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature; 242 242 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 243 -* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on __theminimum cellU,,ocv,, voltage__ (corrected due to current and cell resistance)243 +* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on minimum cell voltage; 244 244 * Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage; 245 245 * Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature; 246 246 * Option 4: Cell voltage x Factor – the dependence of the correction factor on minimum cell temperature. ... ... @@ -297,15 +297,13 @@ 297 297 298 298 To change the parameters of charging process status, select the "Control → Charging status" section: 299 299 300 -[[image:17 54931617275-503.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="135" width="800"]]300 +[[image:1740399071280-626.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="123" width="800"]] 301 301 In this section: 302 302 303 303 * Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 304 304 * Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 305 -* Use actual voltage to generate the "Ready to charge" signal – a flag to disable voltage correction for "Ready to charge" signal; 306 -* Use actual voltage to generate the "Ready to charge" signal if the current is negative – a flag to disable voltage correction for "Ready to charge" signal only at discharging current; 307 -* Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 308 -* Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 305 +* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 306 +* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 309 309 * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 310 310 * Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal. 311 311 ... ... @@ -320,13 +320,13 @@ 320 320 321 321 To change the parameters of discharging process status, select the "Control → Discharging status" section: 322 322 323 -[[image:17 54931699901-802.png]]321 +[[image:1740399096018-240.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="110" width="800"]] 324 324 In this section: 325 325 326 326 * Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А; 327 327 * Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А; 328 -* Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;329 -* Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;326 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 327 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 330 330 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 331 331 332 332 === Precharge === ... ... @@ -539,35 +539,27 @@ 539 539 540 540 === Cell balancing === 541 541 542 -Balancing makes the voltage of all cells equal to the minimum cell voltage. 540 +Balancing makes the voltage of all cells be equal to the minimum cell voltage. 543 543 544 544 The following balancing rules are supported: 545 545 546 -* when the battery is charging (current I > 0) and timeafteruntil the battery is relaxed;544 +* only when the battery is charging (current I > 0) and some time until the battery is relaxed; 547 547 * when the battery is charging (current I > 0) or when the battery is in a state of relaxation; 548 548 * always (regardless of battery state). 549 549 550 -A balancing resistor is connected to the cell if the following conditions are simultaneously met:548 +A balancing resistor is connected to the cell if: 551 551 552 -* the voltage on the cell is higher than the balancingstart voltage;553 -* the difference between the voltage on the celland the minimum voltage among the batterycellsis greater than the balancingstartthreshold;550 +* the voltage on the cell is higher than the starting voltage of the balancing; 551 +* the difference between the cell voltage and the minimum voltage among the cells of the battery is greater than the balancing deviation. 554 554 555 -A balancing resistor is disconnected from the cell if any of the following conditions are met: 556 - 557 -* the voltage on the cell is less than the balancing stop voltage; 558 -* the difference between the voltage on the cell and the minimum voltage among the battery cells is less than the balancing stop threshold. 559 - 560 560 (% class="box infomessage" %) 561 561 ((( 562 -If the “Highlogictemperature” occurs, then the balancing of the cells connected to the overheated BMS Logicdevice will not be performed.555 +If the BMS Mini overheats, then the balancing of the cells connected to this device will not be performed. 563 563 ))) 564 564 565 -The BMS Mini device can enable the cell balancing by the external “Balancing request” signal. Balancing process will be started to cells which the voltage is higher than the balancing start voltage and the difference between the cell voltage and the minimum voltage among all the cells is greater than the balancing stop threshold. 566 - 567 -BMS Mini device can force a cell balancing, if its voltage is higher than estimated value. 568 - 569 569 To change the cell balancing parameters, select the "Control → Cell balancing" section: 570 570 560 + 571 571 [[image:1740404562825-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]] 572 572 In this section: 573 573 ... ... @@ -576,15 +576,11 @@ 576 576 ** Balance on charge; 577 577 ** Balance on charge or relaxed; 578 578 ** Balance always; 579 - * Balancing condition:580 - ** Automatic – balancingwill beerformedutomaticallyifneededconditionsaremet;581 - ** On balancing request – balancing will start only if a remote request is received. In this case cells will start to balance regardless the "Voltage deviation to start balancing" value;569 + 570 +[[image:1733746797004-660.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="104" width="800"]] 571 + 582 582 * Minimum cell voltage to start balancing, V; 583 -* Voltage deviation to start balancing; 584 -* Voltage deviation to stop balancing; 585 -* Voltage for forced balancing – if cell voltage is above this value, it will start discharging through balancing resistor; 586 -* Maximum allowable temperature of the board, ºC; 587 -* Command to discharge all cells – a flag to force the balancing of all cells. 573 +* Balancing deviation, V. 588 588 589 589 === Power down === 590 590 ... ... @@ -599,20 +599,20 @@ 599 599 600 600 To change the parameters of the power down control, select the "Control → Power down" section: 601 601 602 -[[image:1740404859367-943.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]] 588 +[[image:1733746797005-459.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="115" width="800"]] 589 + 603 603 In this section: 604 604 605 605 * Minimum voltage to power down – a minimum voltage level of the battery below which the BMS commands to shut down the battery, V; 606 606 * Idle time to power down – a time of battery inactivity after which the battery is shut down, minute; 607 -* Wait the "Power up/down request" is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS; 608 -* Delay before setting the internal power down signal – a delay before turning off the device power when receiving the “Power down request” command, ms. 594 +* Wait the "Power up/down request" is cleared (on startup) – a flag to enable delay for clearing the “Power up/down request” signal while starting the BMS. 609 609 610 610 === Heater === 611 611 612 612 To change the parameters of the heater control algorithm, select the "Control → Heater" section: 613 613 600 +[[image:1733746808496-606.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]] 614 614 615 -[[image:1740404973346-344.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 616 616 In this section: 617 617 618 618 * Enable – a flag to enable heater control; ... ... @@ -620,7 +620,7 @@ 620 620 * Tolerant cell temperature, °C; 621 621 * Delay before starting the heater, millisecond; 622 622 * Delay before stopping the heater, millisecond; 623 -* Errors 1, 2toturnoff the heater–bitfieldsto chooseeerrorswhich willturnofftheheater.609 +* Switch off the heater on errors (Undervoltage, Overcurrent, High temperature, Short circuit or Critical error). 624 624 625 625 As a result of operating the heating algorithm, the “Heater” signal is generated. 626 626 ... ... @@ -641,8 +641,8 @@ 641 641 642 642 To change the parameters of the cooler control algorithm, select the "Control → Cooler" section: 643 643 630 +[[image:1733746808497-424.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]] 644 644 645 -[[image:1740405145695-704.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]] 646 646 In this section: 647 647 648 648 * Enable – a flag to enable cooler control; ... ... @@ -650,7 +650,7 @@ 650 650 * Tolerant cell temperature, °C; 651 651 * Delay before starting the cooler, millisecond; 652 652 * Delay before stopping the cooler, millisecond; 653 -* Errors 1, 2toturnoff theheater–bitfieldstochoosethe errorswhichwillturnoffthecooler.639 +* Switch off the cooler contactor on errors (Undervoltage, Overcurrent, Low temperature, Short circuit or Critical error). 654 654 655 655 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 656 656
- 1740405145695-704.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.6 KB - Content
- 1754931617275-503.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.8 KB - Content
- 1754931699901-802.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -30.3 KB - Content