Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -208,11 +208,11 @@ 208 208 * Enable – a flag to start calculation of the charge current limit; 209 209 * Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A; 210 210 * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 211 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on SOC and battery temperature; 211 +* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on __maximum cell SOC__ and battery temperature; 212 212 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 213 213 * Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature; 214 214 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 215 -* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on maximum cell voltage ;215 +* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on __the maximum cell U,,ocv,, voltage__ (corrected due to current and cell resistance) 216 216 * Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage; 217 217 * Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature; 218 218 * Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature. ... ... @@ -236,11 +236,11 @@ 236 236 * Enable – a flag to start calculation of the discharge current limit; 237 237 * Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions), A; 238 238 * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 239 -* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on SOC and temperature; 239 +* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on __minimum cell SOC__ and temperature; 240 240 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 241 241 * Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature; 242 242 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 243 -* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on minimum cell voltage ;243 +* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on __the minimum cell U,,ocv,, voltage__ (corrected due to current and cell resistance) 244 244 * Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage; 245 245 * Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature; 246 246 * Option 4: Cell voltage x Factor – the dependence of the correction factor on minimum cell temperature. ... ... @@ -302,8 +302,8 @@ 302 302 303 303 * Current to set the "Charging current present" – a current level to generate the "Charging current present" signal, A; 304 304 * Current to clear the "Charging current present" – a current level to clear the "Charging current present" signal, A; 305 -* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 306 -* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 305 +* Voltage to clear the “Ready to charge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 306 +* Voltage to reset the “Ready to charge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 307 307 * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0; 308 308 * Errors 1, 2 to clear the "Ready to charge" – bitfields to choose the errors which will clear the "Ready to charge" signal. 309 309 ... ... @@ -323,8 +323,8 @@ 323 323 324 324 * Current to set the "Discharging current present" – a current level to generate the "Discharging current present" signal, А; 325 325 * Current to clear the "Discharging current present" – a current level to clear the "Discharging current present" signal, А; 326 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 327 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 326 +* Voltage to clear the “Ready to discharge” – a threshold U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 327 +* Voltage to reset the “Ready to discharge” – a tolerant U,,ocv,, (corrected due to current and cell resistance) voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 328 328 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 329 329 330 330 === Precharge === ... ... @@ -618,7 +618,7 @@ 618 618 * Tolerant cell temperature, °C; 619 619 * Delay before starting the heater, millisecond; 620 620 * Delay before stopping the heater, millisecond; 621 -* Errors 1, 2 to turn off the heater – bitfields to choose the errors which will turn off the heater ;621 +* Errors 1, 2 to turn off the heater – bitfields to choose the errors which will turn off the heater. 622 622 623 623 As a result of operating the heating algorithm, the “Heater” signal is generated. 624 624 ... ... @@ -639,8 +639,8 @@ 639 639 640 640 To change the parameters of the cooler control algorithm, select the "Control → Cooler" section: 641 641 642 -[[image:1733746808497-424.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="800"]] 643 643 643 +[[image:1740405145695-704.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]] 644 644 In this section: 645 645 646 646 * Enable – a flag to enable cooler control; ... ... @@ -648,7 +648,7 @@ 648 648 * Tolerant cell temperature, °C; 649 649 * Delay before starting the cooler, millisecond; 650 650 * Delay before stopping the cooler, millisecond; 651 -* Switchoff thecooler contactor onerrors(Undervoltage,Overcurrent,Lowtemperature, Shortcircuit orCriticalror).651 +* Errors 1, 2 to turn off the heater – bitfields to choose the errors which will turn off the cooler. 652 652 653 653 As a result of operating the cooling algorithm, the "Cooler" signal is generated. 654 654
- 1740405145695-704.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.6 KB - Content