Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -472,38 +472,13 @@ 472 472 473 473 The BMS Mini device can control the charging/discharging contactor that is used to both charge and discharge the battery. 474 474 475 - Charge/Dischargecontactor has three algorithms ofoperation:475 +The charging/discharging contactor combines algorithms of charging and discharging contactor. It behaves as a charging contactor when «Charge request» or «Charger connected» are set, otherwise – as a discharging contactor. 476 476 477 -* Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 478 -* Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 479 -* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests and closes if one of these signals occurs. 480 - 481 -TBA 482 - 483 -(% class="box infomessage" %) 484 -((( 485 -**Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 486 -))) 487 - 488 488 The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section: 489 489 490 -[[image:174 0400166950-906.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="211" width="800"]]479 +[[image:1733746901779-991.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="95" width="800"]]In this section: 491 491 492 -In this section: 493 - 494 494 * Enable – a flag to enable the charge/discharge controller. 495 -* Algorithm: 496 -** Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 497 -** Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 498 -** Independent (on Charge request or Discharge request); 499 -* Delay before starting charging or discharging, millisecond; 500 -* Delay before stopping charging or discharging, millisecond; 501 -* Control the precharging contactor – a flag that enables control of precharging contactor while closing the charge/discharge contactor; 502 -* Emulate the "Charging" and "Discharging" signals – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor; 503 -* Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes; 504 -* Errors 1, 2 which affect the contactor only if battery CHARGING is detected – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND; 505 -* Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND; 506 -* Switch off the charging/discharging contactor on errors without delay – a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”. 507 507 508 508 === Discharge (AUX) === 509 509 ... ... @@ -519,8 +519,8 @@ 519 519 520 520 To change the parameters of the powering of external equipment, select the "Control → Discharge (AUX)" section: 521 521 497 +[[image:1733746932199-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="800"]] 522 522 523 -[[image:1740400254884-851.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="800"]] 524 524 In this section: 525 525 526 526 * Enable – a flag to activate the auxiliary discharge control; ... ... @@ -527,14 +527,13 @@ 527 527 * Switch off the discharging (AUX) contactor if the SOC is too low; 528 528 * Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %; 529 529 * Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %; 530 -* Switch off the discharging (AUX) contactor if the cell voltage is out of the range; 531 -* Minimum cell voltage, V; 532 -* Maximum cell voltage, V; 533 533 * Switch off the discharging (AUX) contactor if the battery voltage is out of the range; 534 -* Minimum battery voltage, V; 535 -* Maximum battery voltage, V; 536 -* Errors1,2to open the auxiliary discharging contactor–bitfieldsto choosetheerrorswhichwillopeneauxiliarydischargingcontactor.506 +* Minimum voltage – minimum battery voltage, V; 507 +* Maximum voltage – maximum battery voltage, V; 508 +* Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error. 537 537 510 +=== === 511 + 538 538 === Cell balancing === 539 539 540 540 Balancing makes the voltage of all cells be equal to the minimum cell voltage. ... ... @@ -557,8 +557,8 @@ 557 557 558 558 To change the cell balancing parameters, select the "Control → Cell balancing" section: 559 559 534 +[[image:1733746797003-364.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="104" width="800"]] 560 560 561 -[[image:1740404562825-676.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]] 562 562 In this section: 563 563 564 564 * Enable – a flag to enable cell balancing;
- 1740404562825-676.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.4 KB - Content