... ... @@ -409,12 +409,17 @@ 409 409 * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 410 410 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 411 411 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 412 -* Control the precharging contactor – a flag that allows control of the precharging contactor (see [[Precharge>>url:http://#HPrecharge]]);412 +* Control the precharging contactor – a flag that allows control of the precharging contactor; 413 413 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 414 414 * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 415 415 * Custom delay: <error> – specific error delay, millisecond; 416 416 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 417 417 418 +(% class="box infomessage" %) 419 +((( 420 +Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 421 +))) 422 + 418 418 === Discharge === 419 419 420 420 The device controls the discharging contactor to connect battery to the load. ... ... @@ -421,36 +421,50 @@ 421 421 422 422 The device supports three algorithms to control battery discharging: 423 423 424 -* Alwayson – load is always connected;425 -* On charger disconnected –load is connected when there is no signal “Charger connected”;426 -* On discharge request –load is connected when there is signal “Discharge request”.429 +* load is always connected; 430 +* load is connected when there is no signal “Charger connected”; 431 +* load is connected when there is signal “Discharge request”. 427 427 428 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors fromthe "Errors 1, 2 ..." bitfieldsappearsor one of the signals:433 +When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors appears: 429 429 430 -* Service reset 431 -* Power down request 432 -* Inhibit discharging 435 +* Undervoltage; 436 +* Overvoltage (optional); 437 +* Overcurrent; 438 +* High temperature (DCH); 439 +* Low temperature (DCH) (optional); 440 +* HYG offline (optional); 441 +* Combilift offline (optional); 442 +* Spirit offline (optional); 443 +* Spirit charger error (optional); 444 +* Short circuit (optional); 445 +* High contactor temperature (optional); 446 +* DCH contactor cycles error; 447 +* Critical error 433 433 434 434 the discharging contactor opens. 435 435 436 -If the algorithm "**On charger disconnected**" is selected, the control is performed as follows:451 +If the algorithm "**On Charger disconnected**" is selected, the control is performed as follows: 437 437 438 -* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the "Errors1, 2 ..."bitfields), then through the delay time T,,on,, the discharging contactor closes;439 -* If the signal “Charger connected” appears or errors occur (see the "Errors1, 2 ..."bitfields), then after the delay time T,,off,, the discharging contactor opens.453 +* if there is no signal “Charger connected”, the charging contactor is opened and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes; 454 +* If the signal “Charger connected” appears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens. 440 440 441 -When the "**On discharge request**" algorithm selected, the control is performed as follows:456 +When the "**On Discharge request**" algorithm selected, the control is performed as follows: 442 442 443 -* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the "Errors1, 2 ..."bitfields), then through the delay time T,,on,, the discharging contactor closes;444 -* If the signal “Discharge request” disappears or errors occur (see the "Errors1, 2 ..."bitfields), then after the delay time T,,off,, the discharging contactor opens.458 +* if there is signal “Discharge request”, the charging contactor is opened and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes; 459 +* If the signal “Discharge request” disappears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens. 445 445 446 446 (% class="box infomessage" %) 447 447 ((( 448 - **Note:**when errorsoccurin the system, the **Discharge**contactoropenseither immediately or withthedelay T,,off,, (depends on the settings described below).463 +Note: in case of errors in the system operation, the opening of the **discharging **contactor is performed either immediately or with a delay T,,off,, (depends on the settings described below). 449 449 ))) 450 450 466 +The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted. 467 + 468 +When the power down request occurs, the discharging contactor opens after delay T,,off,,. Reclosing the discharging contactor is performed if the power down request is removed. 469 + 451 451 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 452 452 453 -[[image:17 40399783613-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="311" width="800"]]472 +[[image:1733746885414-479.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="319" width="800"]] 454 454 455 455 In this section: 456 456 ... ... @@ -459,51 +459,28 @@ 459 459 ** Always on – load is always connected; 460 460 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 461 461 ** On discharge request – load is connected when there is signal “Discharge request”; 462 -* Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared; 481 +* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А; 482 +* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 463 463 * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 464 464 * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 465 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>path:#HPrecharge]]); 466 -* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor; 467 467 * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 468 468 * Custom delay: <error> – specific error delay, millisecond; 469 469 * Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”. 488 +* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 489 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 490 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 470 470 471 471 === Charge/Discharge === 472 472 473 473 The BMS Mini device can control the charging/discharging contactor that is used to both charge and discharge the battery. 474 474 475 - Charge/Dischargecontactor has three algorithms ofoperation:496 +The charging/discharging contactor combines algorithms of charging and discharging contactor. It behaves as a charging contactor when «Charge request» or «Charger connected» are set, otherwise – as a discharging contactor. 476 476 477 -* Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 478 -* Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 479 -* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests and closes if one of these signals occurs. 480 - 481 -TBA 482 - 483 -(% class="box infomessage" %) 484 -((( 485 -**Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 486 -))) 487 - 488 488 The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section: 489 489 490 -[[image:174 0400166950-906.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="211" width="800"]]500 +[[image:1733746901779-991.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="95" width="800"]]In this section: 491 491 492 -In this section: 493 - 494 494 * Enable – a flag to enable the charge/discharge controller. 495 -* Algorithm: 496 -** Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 497 -** Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 498 -** Independent (on Charge request or Discharge request); 499 -* Delay before starting charging or discharging, millisecond; 500 -* Delay before stopping charging or discharging, millisecond; 501 -* Control the precharging contactor – a flag that enables control of precharging contactor while closing the charge/discharge contactor; 502 -* Emulate the "Charging" and "Discharging" signals – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor; 503 -* Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes; 504 -* Errors 1, 2 which affect the contactor only if battery CHARGING is detected – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND; 505 -* Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND; 506 -* Switch off the charging/discharging contactor on errors without delay – a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”. 507 507 508 508 === Discharge (AUX) === 509 509 ... ... @@ -519,8 +519,8 @@ 519 519 520 520 To change the parameters of the powering of external equipment, select the "Control → Discharge (AUX)" section: 521 521 518 +[[image:1733746932199-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="800"]] 522 522 523 -[[image:1740400254884-851.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="800"]] 524 524 In this section: 525 525 526 526 * Enable – a flag to activate the auxiliary discharge control; ... ... @@ -527,14 +527,13 @@ 527 527 * Switch off the discharging (AUX) contactor if the SOC is too low; 528 528 * Minimum SOC – a minimum SOC value, when reached, the auxiliary (AUX) discharging contactor opens, %; 529 529 * Tolerant SOC – a permissive SOC value, upon reaching which the auxiliary (AUX) discharging contactor re-closes, %; 530 -* Switch off the discharging (AUX) contactor if the cell voltage is out of the range; 531 -* Minimum cell voltage, V; 532 -* Maximum cell voltage, V; 533 533 * Switch off the discharging (AUX) contactor if the battery voltage is out of the range; 534 -* Minimum battery voltage, V; 535 -* Maximum battery voltage, V; 536 -* Errors1,2to open the auxiliary discharging contactor–bitfieldsto choosetheerrorswhichwillopeneauxiliarydischargingcontactor.527 +* Minimum voltage – minimum battery voltage, V; 528 +* Maximum voltage – maximum battery voltage, V; 529 +* Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error. 537 537 531 +=== === 532 + 538 538 === Cell balancing === 539 539 540 540 Balancing makes the voltage of all cells be equal to the minimum cell voltage.
- 1740399783613-216.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -59.8 KB - Content
- 1740400166950-906.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -49.2 KB - Content
- 1740400254884-851.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.2 KB - Content