Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:15

From version 27.2
edited by Admin
on 2025/02/24 12:30
Change comment: There is no comment for this version
To version 27.1
edited by Admin
on 2025/02/24 12:30
Change comment: Uploaded new attachment "1740400254884-851.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -472,38 +472,13 @@
472 472  
473 473  The BMS Mini device can control the charging/discharging contactor that is used to both charge and discharge the battery.
474 474  
475 -Charge/Discharge contactor has three algorithms of operation:
475 +The charging/discharging contactor combines algorithms of charging and discharging contactor. It behaves as a charging contactor when «Charge reques or «Charger connected» are set, otherwise – as a discharging contactor.
476 476  
477 -* Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor;
478 -* Independent (Always) - Charge/Discharge contactor is always closed if there is no errors;
479 -* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests and closes if one of these signals occurs.
480 -
481 -TBA
482 -
483 -(% class="box infomessage" %)
484 -(((
485 -**Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
486 -)))
487 -
488 488  The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section:
489 489  
490 -[[image:1740400166950-906.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="211" width="800"]]
479 +[[image:1733746901779-991.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="95" width="800"]]In this section:
491 491  
492 -In this section:
493 -
494 494  * Enable – a flag to enable the charge/discharge controller.
495 -* Algorithm:
496 -** Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor;
497 -** Independent (Always) - Charge/Discharge contactor is always closed if there is no errors;
498 -** Independent (on Charge request or Discharge request);
499 -* Delay before starting charging or discharging, millisecond;
500 -* Delay before stopping charging or discharging, millisecond;
501 -* Control the precharging contactor – a flag that enables control of precharging contactor while closing the charge/discharge contactor;
502 -* Emulate the "Charging" and "Discharging" signals – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor;
503 -* Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes;
504 -* Errors 1, 2 which affect the contactor only if battery CHARGING is detected – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND;
505 -* Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND;
506 -* Switch off the charging/discharging contactor on errors without delay – a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”.
507 507  
508 508  === Discharge (AUX) ===
509 509  
... ... @@ -519,9 +519,8 @@
519 519  
520 520  To change the parameters of the powering of external equipment, select the "Control → Discharge (AUX)" section:
521 521  
497 +[[image:1733746932199-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="137" width="800"]]
522 522  
523 -[[image:1740400254884-851.png]]
524 -
525 525  In this section:
526 526  
527 527  * Enable – a flag to activate the auxiliary discharge control;