... ... @@ -409,12 +409,17 @@
409 409  * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
410 410  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
411 411  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
412 -* Control the precharging contactor – a flag that allows control of the precharging contactor (see [[Precharge>>url:http://#HPrecharge]]);
412 +* Control the precharging contactor – a flag that allows control of the precharging contactor;
413 413  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
414 414  * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor;
415 415  * Custom delay: <error> – specific error delay, millisecond;
416 416  * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”;
417 417  
418 +(% class="box infomessage" %)
419 +(((
420 +Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor.
421 +)))
422 +
418 418  === Discharge ===
419 419  
420 420  The device controls the discharging contactor to connect battery to the load.
... ... @@ -421,36 +421,50 @@
421 421  
422 422  The device supports three algorithms to control battery discharging:
423 423  
424 -* Always on – load is always connected;
425 -* On charger disconnected – load is connected when there is no signal “Charger connected”;
426 -* On discharge request – load is connected when there is signal “Discharge request”.
429 +* load is always connected;
430 +* load is connected when there is no signal “Charger connected”;
431 +* load is connected when there is signal “Discharge request”.
427 427  
428 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
433 +When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors appears:
429 429  
430 -* Service reset
431 -* Power down request
432 -* Inhibit discharging
435 +* Undervoltage;
436 +* Overvoltage (optional);
437 +* Overcurrent;
438 +* High temperature (DCH);
439 +* Low temperature (DCH) (optional);
440 +* HYG offline (optional);
441 +* Combilift offline (optional);
442 +* Spirit offline (optional);
443 +* Spirit charger error (optional);
444 +* Short circuit (optional);
445 +* High contactor temperature (optional);
446 +* DCH contactor cycles error;
447 +* Critical error
433 433  
434 434  the discharging contactor opens.
435 435  
436 -If the algorithm "**On charger disconnected**" is selected, the control is performed as follows:
451 +If the algorithm "**On Charger disconnected**" is selected, the control is performed as follows:
437 437  
438 -* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes;
439 -* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens.
453 +* if there is no signal “Charger connected”, the charging contactor is opened and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
454 +* If the signal “Charger connected” appears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
440 440  
441 -When the "**On discharge request**" algorithm selected, the control is performed as follows:
456 +When the "**On Discharge request**" algorithm selected, the control is performed as follows:
442 442  
443 -* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes;
444 -* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens.
458 +* if there is signal “Discharge request”, the charging contactor is opened and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
459 +* If the signal “Discharge request” disappears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
445 445  
446 446  (% class="box infomessage" %)
447 447  (((
448 -**Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
463 +Note: in case of errors in the system operation, the opening of the **discharging **contactor is performed either immediately or with a delay T,,off,, (depends on the settings described below).
449 449  )))
450 450  
466 +The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted.
467 +
468 +When the power down request occurs, the discharging contactor opens after delay T,,off,,. Reclosing the discharging contactor is performed if the power down request is removed.
469 +
451 451  To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section:
452 452  
453 -[[image:1740399783613-216.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="311" width="800"]]
472 +[[image:1733746885414-479.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="319" width="800"]]
454 454  
455 455  In this section:
456 456  
... ... @@ -459,14 +459,16 @@
459 459  ** Always on – load is always connected;
460 460  ** On charger disconnected – load is connected when there is no signal “Charger connected”;
461 461  ** On discharge request – load is connected when there is signal “Discharge request”;
462 -* Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared;
481 +* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А;
482 +* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А;
463 463  * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond;
464 464  * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond;
465 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor (see [[Precharge>>path:#HPrecharge]]);
466 -* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor;
467 467  * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
468 468  * Custom delay: <error> – specific error delay, millisecond;
469 469  * Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”.
488 +* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;
489 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
490 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
470 470  
471 471  === Charge/Discharge ===
472 472  
1740399783613-216.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -59.8 KB
Content