- Content
-
... ... @@ -409,7 +409,7 @@ 409 409 * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 410 410 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 411 411 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 412 -* Control the precharging contactor – a flag that allows control of the precharging contactor; 412 +* Control the precharging contactor – a flag that allows control of the precharging contactor (see [[Precharge>>url:http://#HPrecharge]]); 413 413 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 414 414 * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 415 415 * Custom delay: <error> – specific error delay, millisecond;
- 1740399783613-216.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.8 KB - Content