... ... @@ -409,17 +409,12 @@ 409 409 * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 410 410 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 411 411 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 412 -* Control the precharging contactor – a flag that allows control of the precharging contactor; 412 +* Control the precharging contactor – a flag that allows control of the precharging contactor (see [[Precharge>>url:http://#HPrecharge]]); 413 413 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 414 414 * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 415 415 * Custom delay: <error> – specific error delay, millisecond; 416 416 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 417 417 418 -(% class="box infomessage" %) 419 -((( 420 -Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 421 -))) 422 - 423 423 === Discharge === 424 424 425 425 The device controls the discharging contactor to connect battery to the load. ... ... @@ -487,7 +487,7 @@ 487 487 * Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”. 488 488 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 489 489 * Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 490 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set ;485 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set. 491 491 492 492 === Charge/Discharge === 493 493
- 1740399783613-216.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.8 KB - Content