- Content
-
... ... @@ -364,40 +364,51 @@ 364 364 365 365 The device supports three charge control algorithms: 366 366 367 -* Always on –charging is always allowed;368 -* Oncharger connected – charging is allowed when there is a signal “Charger connected”;369 -* Oncharge request – charging is allowed when there is a signal “Charge request”.367 +* charging is always allowed; 368 +* charging is allowed when there is a signal “Charger connected”; 369 +* charging is allowed when there is a signal “Charge request”. 370 370 371 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfieldsappearsor one of the signals:371 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears: 372 372 373 -* Service reset; 374 -* Power down request; 375 -* Inhibit charging, 373 +* Overvoltage; 374 +* Overcurrent; 375 +* High temperature (CH); 376 +* Low temperature (CH); 377 +* HYG offline (optional); 378 +* Combilift offline (optional); 379 +* Spirit offline (optional); 380 +* Spirit charger error (optional); 381 +* Short circuit (optional); 382 +* High contactor temperature (optional); 383 +* CH contactor cycles error; 384 +* Critical error 376 376 377 377 both contactors are open (no current flows). 378 378 379 -When the algorithm "**On charger connected**" is selected, the control is performed as follows:388 +When the algorithm "**On Charger connected**" is selected, the control is performed as follows: 380 380 381 -* If there is a signal “Charger connected” and there are no errors (see the "Errors1, 2 ..."bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;390 +* If there is a signal “Charger connected” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 382 382 * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 383 383 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 384 -* If errors fromthe"Errors1, 2 ..."bitfieldsoccur the charging contactor and allow charging contactor open.393 +* If errors in the list above occur the charging contactor and allow charging contactor open. 385 385 386 -When the "**On charge request**" algorithm selected, the control is performed as follows:395 +When the "**On Charge request**" algorithm selected, the control is performed as follows: 387 387 388 -* If there is a signal “Charge request” and there are no errors (see the "Errors1, 2 ..."bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;397 +* If there is a signal “Charge request” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close; 389 389 * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens; 390 390 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 391 -* If errors fromthe"Errors1, 2 ..."bitfieldsoccur the charging contactor and allow charging contactor open.400 +* If errors in the list above occur the charging contactor and allow charging contactor open. 392 392 393 393 (% class="box infomessage" %) 394 394 ((( 395 - **Note:**when errors occur in the system, the **Charge**contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).404 +Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 396 396 ))) 397 397 407 +When the power down request occurs, the allow charging contactor opens immediately and the charging contactor opens after the delay T,,off,,. Reclosing the charging contactor and allow charging contactor is performed if the power down request is removed. 408 + 398 398 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 399 399 400 -[[image:17 40399363134-722.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="306" width="800"]]411 +[[image:1733746766516-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="319" width="800"]] 401 401 402 402 In this section: 403 403