364 364  
365 365  The device supports three charge control algorithms:
366 366  
367 -* charging is always allowed;
368 -* charging is allowed when there is a signal “Charger connected”;
369 -* charging is allowed when there is a signal “Charge request”.
367 +* Always on – charging is always allowed;
368 +* On charger connected – charging is allowed when there is a signal “Charger connected”;
369 +* On charge request – charging is allowed when there is a signal “Charge request”.
370 370  
371 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears:
371 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
372 372  
373 -* Overvoltage;
374 -* Overcurrent;
375 -* High temperature (CH);
376 -* Low temperature (CH);
377 -* HYG offline (optional);
378 -* Combilift offline (optional);
379 -* Spirit offline (optional);
380 -* Spirit charger error (optional);
381 -* Short circuit (optional);
382 -* High contactor temperature (optional);
383 -* CH contactor cycles error;
384 -* Critical error
373 +* Service reset;
374 +* Power down request;
375 +* Inhibit charging,
385 385  
386 386  both contactors are open (no current flows).
387 387  
388 -When the algorithm "**On Charger connected**" is selected, the control is performed as follows:
379 +When the algorithm "**On charger connected**" is selected, the control is performed as follows:
389 389  
390 -* If there is a signal “Charger connected” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
381 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
391 391  * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
392 392  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
393 -* If errors in the list above occur the charging contactor and allow charging contactor open.
384 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
394 394  
395 -When the "**On Charge request**" algorithm selected, the control is performed as follows:
386 +When the "**On charge request**" algorithm selected, the control is performed as follows:
396 396  
397 -* If there is a signal “Charge request” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
388 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
398 398  * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
399 399  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
400 -* If errors in the list above occur the charging contactor and allow charging contactor open.
391 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
401 401  
402 402  (% class="box infomessage" %)
403 403  (((
404 -Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
395 +**Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
405 405  )))
406 406  
407 -When the power down request occurs, the allow charging contactor opens immediately and the charging contactor opens after the delay T,,off,,. Reclosing the charging contactor and allow charging contactor is performed if the power down request is removed.
408 -
409 409  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
410 410  
411 -[[image:1733746766516-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="319" width="800"]]
400 +[[image:1740399363134-722.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="306" width="800"]]
412 412  
413 413  In this section:
414 414