... ... @@ -338,7 +338,6 @@
338 338  To change the parameters of precharge contactor, select the "Control → Precharge" section:
339 339  
340 340  * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A;
341 -* Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V;
342 342  * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error";
343 343  * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;
344 344  * Relaxation between attempts – a duration between precharge attempts, millisecond;
... ... @@ -352,7 +352,6 @@
352 352  “Precharge error” generation conditions if any of the following is true:
353 353  
354 354  * the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts";
355 -* voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts";
356 356  * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time.
357 357  
358 358  (% class="box warningmessage" %)
... ... @@ -366,51 +366,40 @@
366 366  
367 367  The device supports three charge control algorithms:
368 368  
369 -* charging is always allowed;
370 -* charging is allowed when there is a signal “Charger connected”;
371 -* charging is allowed when there is a signal “Charge request”.
367 +* Always on – charging is always allowed;
368 +* On charger connected – charging is allowed when there is a signal “Charger connected”;
369 +* On charge request – charging is allowed when there is a signal “Charge request”.
372 372  
373 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears:
371 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
374 374  
375 -* Overvoltage;
376 -* Overcurrent;
377 -* High temperature (CH);
378 -* Low temperature (CH);
379 -* HYG offline (optional);
380 -* Combilift offline (optional);
381 -* Spirit offline (optional);
382 -* Spirit charger error (optional);
383 -* Short circuit (optional);
384 -* High contactor temperature (optional);
385 -* CH contactor cycles error;
386 -* Critical error
373 +* Service reset;
374 +* Power down request;
375 +* Inhibit charging,
387 387  
388 388  both contactors are open (no current flows).
389 389  
390 -When the algorithm "**On Charger connected**" is selected, the control is performed as follows:
379 +When the algorithm "**On charger connected**" is selected, the control is performed as follows:
391 391  
392 -* If there is a signal “Charger connected” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
381 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
393 393  * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
394 394  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
395 -* If errors in the list above occur the charging contactor and allow charging contactor open.
384 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
396 396  
397 -When the "**On Charge request**" algorithm selected, the control is performed as follows:
386 +When the "**On charge request**" algorithm selected, the control is performed as follows:
398 398  
399 -* If there is a signal “Charge request” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
388 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
400 400  * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
401 401  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
402 -* If errors in the list above occur the charging contactor and allow charging contactor open.
391 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
403 403  
404 404  (% class="box infomessage" %)
405 405  (((
406 -Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
395 +**Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
407 407  )))
408 408  
409 -When the power down request occurs, the allow charging contactor opens immediately and the charging contactor opens after the delay T,,off,,. Reclosing the charging contactor and allow charging contactor is performed if the power down request is removed.
410 -
411 411  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
412 412  
413 -[[image:1733746766516-845.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="319" width="800"]]
400 +[[image:1740399363134-722.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="306" width="800"]]
414 414  
415 415  In this section:
416 416  
1740399363134-722.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +57.2 KB
Content