Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -338,7 +338,6 @@ 338 338 To change the parameters of precharge contactor, select the "Control → Precharge" section: 339 339 340 340 * Precharge current threshold to finish precharging – a minimum current value at which precharging process assumed to be finished, A; 341 -* Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 342 342 * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 343 343 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 344 344 * Relaxation between attempts – a duration between precharge attempts, millisecond; ... ... @@ -352,7 +352,6 @@ 352 352 “Precharge error” generation conditions if any of the following is true: 353 353 354 354 * the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts"; 355 -* voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts"; 356 356 * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 357 357 358 358 (% class="box warningmessage" %)