Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -229,70 +229,31 @@ 229 229 230 230 To configure parameters for determining the discharge current limit, select the "Control → Discharge map" section: 231 231 232 -[[image:17 40397304972-174.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="182" width="800"]]232 +[[image:1733746766511-477.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]] 233 233 234 234 In this section: 235 235 236 236 * Enable – a flag to start calculation of the discharge current limit; 237 -* Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions), A; 238 -* Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 239 -* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on SOC and temperature; 237 +* Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions): 238 +* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 240 240 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 241 -* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature; 242 -* Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 243 -* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on minimum cell voltage; 244 -* Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage; 245 -* Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature; 246 -* Option 4: Cell voltage x Factor – the dependence of the correction factor on minimum cell temperature. 247 247 248 - Value of the dischargecurrentlimit at given SOC, temperature, contactorsmperature, minimumcell voltageandmaximum celltemperature is calculatedas follows:241 +[[image:1733746766512-300.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="195" width="800"]] 249 249 250 -**Discharge current limit = Maximum discharge current × Kds × Kdc × Kdv × Kdt** 243 +* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on contactor temperature; 244 +* Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 251 251 252 - === Mainontactor ===246 +[[image:1733746766513-161.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="183" width="800"]] 253 253 254 -The BMS Mini device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactors. 248 +* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on minimum cell voltage; 249 +* Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage. 255 255 256 - TheMaincontactor algorithmupportsthefollowingmodes:251 +[[image:1733746766514-686.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="215" width="800"]] 257 257 258 -* Always on; 259 -* Automatic. 253 +Value of the discharge current limit at given SOC, temperature, contactors temperature and minimum cell voltage is calculated as follows: 260 260 261 - In “Alwayson” mode main contactorclosesifallthe followingis true:255 +Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv 262 262 263 -* Other contactors are open; 264 -* There are no errors from the "Errors 1, 2 ..." bitfileds. 265 - 266 -In “Always on” mode main contactor opens if all the following is true: 267 - 268 -* Other contactors are open; 269 -* There is an error from the the "Errors 1, 2 ..." bitfileds. 270 - 271 -In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 272 - 273 -In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 274 - 275 -(% class="box infomessage" %) 276 -((( 277 -**Note: **when errors occur in the system, the **Main **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 278 -))) 279 - 280 -To change the parameters of the main contactor, select the "Control → Main contactor" section: 281 - 282 -[[image:1740397558976-651.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]] 283 - 284 -In this section: 285 - 286 -* Enable – a flag to enable the main contactor control; 287 -* Algorithm – main contactor control algorithm: 288 -** Always on – contactor is always closed; 289 -** Automatic – contactor closes by internal charge and discharge algorithms; 290 -** On demand – contactor is closed by an external request; 291 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 292 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 293 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset; 294 -* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor. 295 - 296 296 === Charge === 297 297 298 298 There are two contactors that serve charging the battery: a charging contactor and an allow charging contactor. With the help of the allow charging contactor, the BMS commands the charger to start or stop charging. ... ... @@ -477,8 +477,38 @@ 477 477 * Maximum voltage – maximum battery voltage, V; 478 478 * Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error. 479 479 480 -=== === 441 +=== Main contactor === 481 481 443 +The BMS Mini device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactors. 444 + 445 +The main contactor closes if there are no errors from the list below: 446 + 447 +* Overcurrent; 448 +* Undervoltage; 449 +* Overvoltage; 450 +* High temperature (CH); 451 +* High temperature (DCH); 452 +* Unallowable charging; 453 +* Critical error. 454 + 455 +The main contactor opens if the charging and discharging contactors are opened and any of the following conditions is met: 456 + 457 +* charging or discharging current is detected during a set time; 458 +* voltage of any cell is lower than the minimum cell voltage configured in the section "Protections → Undervoltage" during a set time; 459 +* voltage of any cell is greater than the maximum cell voltage configured in the section "Protections → Overvoltage" during a set time; 460 +* temperature of any cell is greater than the maximum cell temperature configured in the section "Protections → High temperature" during a set time; 461 +* Critical error stays on during a set time. 462 + 463 +To change the parameters of the main contactor, select the "Control → Main contactor" section: 464 + 465 +[[image:1733746797002-498.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]] 466 + 467 +In this section: 468 + 469 +* Enable – a flag to enable the main contactor control; 470 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 471 +* Keep the contactor open until the device is restarted – a flag for keeping the main contactor opened until the system be reset. 472 + 482 482 === Cell balancing === 483 483 484 484 Balancing makes the voltage of all cells be equal to the minimum cell voltage.
- 1740399019469-925.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.2 KB - Content