Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:15

From version 16.1
edited by Admin
on 2025/02/24 11:41
Change comment: Загрузить новое вложение 1740397290506-387.png
To version 7.1
edited by Admin
on 2025/02/24 10:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -102,26 +102,18 @@
102 102  
103 103  Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value
104 104  
105 -{{formula fontSize="SMALL" imageType="PNG"}}
106 -R = \frac{U-U_{ocv}}{I_{stable}}
107 -{{/formula}}
105 +R = (U-U,,ocv,,) / I,,stable,,,
108 108  
109 109  where U is the cell voltage measured in the charge or discharge state, V; U,,ocv,, is the cell voltage measured in the state of relaxation (before switching to the state of charge or discharge); I,,stable,, – stabilized current through the cell in the state of charge or discharge.
110 110  
111 111  The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance:
112 112  
113 -{{formula fontSize="SMALL"}}
114 -R = \frac{U_2-U_1}{I_{stable2}-I_{stable1}}
115 -{{/formula}}
111 +R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,,
116 116  
117 -provided that
113 +(Q,,max,, is the maximum cell capacity),
118 118  
119 -{{formula fontSize="SMALL"}}
120 -| I_{stable2}-I_{stable1} | > 0.2 × Qmax
121 -{{/formula}}
115 +where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it.
122 122  
123 -where Q,,max,, — the maximum cell capacity,U,,2,, — voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, — the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it.
124 -
125 125  The stabilized current I,,stable,, = I, if during the stabilization time the instantaneous current I is in the range from 0.95 × I to 1.05 × I.
126 126  
127 127  To change parameters of the algorithm for calculating the cell resistance, select the "Control → Resistance estimation" section:
... ... @@ -138,62 +138,6 @@
138 138  
139 139  The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
140 140  
141 -=== Low SOC (signal) ===
142 -
143 -To change the parameters of the generation a signal about low battery level, select the "Control → Low SOC (signal)" section:
144 -
145 -[[image:1740396460923-423.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]]
146 -
147 -In this section:
148 -
149 -* Enable – a flag to enable signal generation;
150 -* Minimum SOC, %;
151 -* Tolerant SOC, %;
152 -* Delay before setting the signal, second;
153 -* Delay before clearing the signal, second;
154 -* Lock – lock the signal until the device is reset.
155 -
156 -Signal generation conditions:
157 -
158 -* the battery SOC is less than the “Minimum SOC” value during the “Delay before setting the signal” time.
159 -
160 -Conditions for clearing the signal:
161 -
162 -* the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time.
163 -
164 -(% class="box infomessage" %)
165 -(((
166 -The "Low SOC signal" is indicative and can be output to a discrete output or a power switch.
167 -)))
168 -
169 -=== High charging current (signal) ===
170 -
171 -To change the parameters of the generation high-current signal, select the "Control → High charging current (signal)" section:
172 -
173 -[[image:1740396996935-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]]
174 -
175 -In this section:
176 -
177 -* Enable – a flag to enable signal generation;
178 -* Maximum charging current, А;
179 -* Tolerant charging current, А;
180 -* Delay before setting the signal, second;
181 -* Delay before clearing the signal, second;
182 -* Lock – lock the signal until the device is reset.
183 -
184 -Signal generation conditions:
185 -
186 -* the measured current is greater than the “Maximum charging current” value during the “Delay before setting the signal” time.
187 -
188 -Conditions for clearing the signal:
189 -
190 -* the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time.
191 -
192 -(% class="box infomessage" %)
193 -(((
194 -The "High charging current" signal is indicative and can be output to a discrete output or a power switch.
195 -)))
196 -
197 197  === Charge map ===
198 198  
199 199  The BMS Mini device calculates maximum allowable charge current values in respect to SOC, battery temperature, contactor temperature and cell voltage.
... ... @@ -202,25 +202,31 @@
202 202  
203 203  To configure parameters for determining the charge current limit, select the "Control → Charge map" section:
204 204  
205 -[[image:1740397188247-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="800"]]
141 +[[image:1733746766504-864.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
142 +
206 206  In this section:
207 207  
208 208  * Enable – a flag to start calculation of the charge current limit;
209 -* Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A;
210 -* Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s;
211 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on SOC and battery temperature;
146 +* Maximum charge current – a maximum allowable value of the charge current (under normal conditions):
147 +* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and battery temperature;
212 212  * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature;
213 -* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature;
149 +
150 +[[image:1733746766506-660.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="196" width="800"]]
151 +
152 +* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on contactor temperature;
214 214  * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature;
215 -* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on maximum cell voltage;
216 -* Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage;
217 -* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature;
218 -* Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature.
219 219  
220 -Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows:
155 +[[image:1733746766508-178.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="184" width="800"]]
221 221  
222 -**Charge current limit = Maximum charge current × Kcs × Kcc × Kcv × Kct**
157 +* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage;
158 +* Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage.
223 223  
160 +[[image:1733746766509-971.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="217" width="800"]]
161 +
162 +Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows:
163 +
164 +Charging current limit = Maximum charging current × Kcs × Kcc × Kcv
165 +
224 224  === Discharge map ===
225 225  
226 226  The BMS Mini device calculates maximum allowable discharge current values in respect to SOC, battery temperature, contactor temperature and cell voltage.
1740396388810-840.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.6 KB
Content
1740396445096-172.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -21.8 KB
Content
1740396460923-423.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -21.8 KB
Content
1740396670709-638.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -19.5 KB
Content
1740396996935-403.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -21.7 KB
Content
1740397115348-751.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -31.2 KB
Content
1740397167225-463.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -44.4 KB
Content
1740397188247-315.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -49.0 KB
Content
1740397290506-387.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -44.2 KB
Content