Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:15

From version 15.1
edited by Admin
on 2025/02/24 11:39
Change comment: Uploaded new attachment "1740397188247-315.png", version {1}
To version 18.1
edited by Admin
on 2025/02/24 11:44
Change comment: Загрузить новое вложение 1740397476082-826.png

Summary

Details

Page properties
Content
... ... @@ -202,31 +202,25 @@
202 202  
203 203  To configure parameters for determining the charge current limit, select the "Control → Charge map" section:
204 204  
205 -[[image:1733746766504-864.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]]
206 -
205 +[[image:1740397188247-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="800"]]
207 207  In this section:
208 208  
209 209  * Enable – a flag to start calculation of the charge current limit;
210 -* Maximum charge current – a maximum allowable value of the charge current (under normal conditions):
211 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and battery temperature;
209 +* Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A;
210 +* Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s;
211 +* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on SOC and battery temperature;
212 212  * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature;
213 -
214 -[[image:1733746766506-660.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="196" width="800"]]
215 -
216 -* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on contactor temperature;
213 +* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature;
217 217  * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature;
215 +* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on maximum cell voltage;
216 +* Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage;
217 +* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature;
218 +* Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature.
218 218  
219 -[[image:1733746766508-178.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="184" width="800"]]
220 +Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows:
220 220  
221 -* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage;
222 -* Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage.
222 +**Charge current limit = Maximum charge current × Kcs × Kcc × Kcv × Kct**
223 223  
224 -[[image:1733746766509-971.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="217" width="800"]]
225 -
226 -Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows:
227 -
228 -Charging current limit = Maximum charging current × Kcs × Kcc × Kcv
229 -
230 230  === Discharge map ===
231 231  
232 232  The BMS Mini device calculates maximum allowable discharge current values in respect to SOC, battery temperature, contactor temperature and cell voltage.
1740397290506-387.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +44.2 KB
Content
1740397304972-174.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +48.0 KB
Content
1740397476082-826.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.6 KB
Content