Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -166,6 +166,34 @@ 166 166 The "Low SOC signal" is indicative and can be output to a discrete output or a power switch. 167 167 ))) 168 168 169 +=== High charging current (signal) === 170 + 171 +To change the parameters of the generation high-current signal, select the "Control → High charging current (signal)" section: 172 + 173 +[[image:1740396996935-403.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]] 174 + 175 +In this section: 176 + 177 +* Enable – a flag to enable signal generation; 178 +* Maximum charging current, А; 179 +* Tolerant charging current, А; 180 +* Delay before setting the signal, second; 181 +* Delay before clearing the signal, second; 182 +* Lock – lock the signal until the device is reset. 183 + 184 +Signal generation conditions: 185 + 186 +* the measured current is greater than the “Maximum charging current” value during the “Delay before setting the signal” time. 187 + 188 +Conditions for clearing the signal: 189 + 190 +* the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 191 + 192 +(% class="box infomessage" %) 193 +((( 194 +The "High charging current" signal is indicative and can be output to a discrete output or a power switch. 195 +))) 196 + 169 169 === Charge map === 170 170 171 171 The BMS Mini device calculates maximum allowable charge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. ... ... @@ -174,31 +174,25 @@ 174 174 175 175 To configure parameters for determining the charge current limit, select the "Control → Charge map" section: 176 176 177 -[[image:1733746766504-864.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="138" width="800"]] 178 - 205 +[[image:1740397188247-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="800"]] 179 179 In this section: 180 180 181 181 * Enable – a flag to start calculation of the charge current limit; 182 -* Maximum charge current – a maximum allowable value of the charge current (under normal conditions): 183 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and battery temperature; 209 +* Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A; 210 +* Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 211 +* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on SOC and battery temperature; 184 184 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 185 - 186 -[[image:1733746766506-660.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="196" width="800"]] 187 - 188 -* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on contactor temperature; 213 +* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature; 189 189 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 215 +* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on maximum cell voltage; 216 +* Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage; 217 +* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature; 218 +* Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature. 190 190 191 - [[image:1733746766508-178.png||data-xwiki-image-style-alignment="center"data-xwiki-image-style-border="true"height="184"width="800"]]220 +Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows: 192 192 193 -* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage; 194 -* Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage. 222 +**Charge current limit = Maximum charge current × Kcs × Kcc × Kcv × Kct** 195 195 196 -[[image:1733746766509-971.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="217" width="800"]] 197 - 198 -Value of the charge current limit at given SOC, temperature, contactors temperature and maximum cell voltage is calculated as follows: 199 - 200 -Charging current limit = Maximum charging current × Kcs × Kcc × Kcv 201 - 202 202 === Discharge map === 203 203 204 204 The BMS Mini device calculates maximum allowable discharge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. ... ... @@ -207,31 +207,70 @@ 207 207 208 208 To configure parameters for determining the discharge current limit, select the "Control → Discharge map" section: 209 209 210 -[[image:173 3746766511-477.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]232 +[[image:1740397304972-174.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="182" width="800"]] 211 211 212 212 In this section: 213 213 214 214 * Enable – a flag to start calculation of the discharge current limit; 215 -* Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions): 216 -* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 237 +* Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions), A; 238 +* Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 239 +* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on SOC and temperature; 217 217 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 241 +* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature; 242 +* Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 243 +* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on minimum cell voltage; 244 +* Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage; 245 +* Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature; 246 +* Option 4: Cell voltage x Factor – the dependence of the correction factor on minimum cell temperature. 218 218 219 - [[image:1733746766512-300.png||data-xwiki-image-style-alignment="center"data-xwiki-image-style-border="true"height="195"width="800"]]248 +Value of the discharge current limit at given SOC, temperature, contactors temperature, minimum cell voltage and maximum cell temperature is calculated as follows: 220 220 221 -* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on contactor temperature; 222 -* Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 250 +**Discharge current limit = Maximum discharge current × Kds × Kdc × Kdv × Kdt** 223 223 224 - [[image:1733746766513-161.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"height="183" width="800"]]252 +=== Main contactor === 225 225 226 -* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on minimum cell voltage; 227 -* Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage. 254 +The BMS Mini device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactors. 228 228 229 - [[image:1733746766514-686.png||data-xwiki-image-style-alignment="center"data-xwiki-image-style-border="true"height="215"width="800"]]256 +The Main contactor algorithm supports the following modes: 230 230 231 -Value of the discharge current limit at given SOC, temperature, contactors temperature and minimum cell voltage is calculated as follows: 258 +* Always on; 259 +* Automatic. 232 232 233 - Dischargingcurrent limit= Maximumdischargingcurrent × Kds× Kdc × Kdv261 +In “Always on” mode main contactor closes if all the following is true: 234 234 263 +* Other contactors are open; 264 +* There are no errors from the "Errors 1, 2 ..." bitfileds. 265 + 266 +In “Always on” mode main contactor opens if all the following is true: 267 + 268 +* Other contactors are open; 269 +* There is an error from the the "Errors 1, 2 ..." bitfileds. 270 + 271 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 272 + 273 +In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 274 + 275 +(% class="box infomessage" %) 276 +((( 277 +**Note: **when errors occur in the system, the **Main **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 278 +))) 279 + 280 +To change the parameters of the main contactor, select the "Control → Main contactor" section: 281 + 282 +[[image:1740397558976-651.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="144" width="800"]] 283 + 284 +In this section: 285 + 286 +* Enable – a flag to enable the main contactor control; 287 +* Algorithm – main contactor control algorithm: 288 +** Always on – contactor is always closed; 289 +** Automatic – contactor closes by internal charge and discharge algorithms; 290 +** On demand – contactor is closed by an external request; 291 +* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 292 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 293 +* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset; 294 +* Errors 1, 2 to open the main contactor – bitfields to choose the errors which will open the main contactor. 295 + 235 235 === Charge === 236 236 237 237 There are two contactors that serve charging the battery: a charging contactor and an allow charging contactor. With the help of the allow charging contactor, the BMS commands the charger to start or stop charging. ... ... @@ -416,38 +416,8 @@ 416 416 * Maximum voltage – maximum battery voltage, V; 417 417 * Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error. 418 418 419 -=== Maincontactor===480 +=== === 420 420 421 -The BMS Mini device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in a case of sealing of the charging or discharging contactors. 422 - 423 -The main contactor closes if there are no errors from the list below: 424 - 425 -* Overcurrent; 426 -* Undervoltage; 427 -* Overvoltage; 428 -* High temperature (CH); 429 -* High temperature (DCH); 430 -* Unallowable charging; 431 -* Critical error. 432 - 433 -The main contactor opens if the charging and discharging contactors are opened and any of the following conditions is met: 434 - 435 -* charging or discharging current is detected during a set time; 436 -* voltage of any cell is lower than the minimum cell voltage configured in the section "Protections → Undervoltage" during a set time; 437 -* voltage of any cell is greater than the maximum cell voltage configured in the section "Protections → Overvoltage" during a set time; 438 -* temperature of any cell is greater than the maximum cell temperature configured in the section "Protections → High temperature" during a set time; 439 -* Critical error stays on during a set time. 440 - 441 -To change the parameters of the main contactor, select the "Control → Main contactor" section: 442 - 443 -[[image:1733746797002-498.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="93" width="800"]] 444 - 445 -In this section: 446 - 447 -* Enable – a flag to enable the main contactor control; 448 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, second; 449 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor opened until the system be reset. 450 - 451 451 === Cell balancing === 452 452 453 453 Balancing makes the voltage of all cells be equal to the minimum cell voltage.
- 1740397115348-751.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.2 KB - Content
- 1740397167225-463.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.4 KB - Content
- 1740397188247-315.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.0 KB - Content
- 1740397290506-387.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.2 KB - Content
- 1740397304972-174.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.0 KB - Content
- 1740397476082-826.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.6 KB - Content
- 1740397558976-651.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +21.7 KB - Content
- 1740399019469-925.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.2 KB - Content