3
4 == Installation procedure ==
5
6 The mounting area of the BMS Mini S must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Mini S is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
7
8 The installation site must provide convenient access for subsequent connection to the device’s headers for connecting other system elements: a current sensor, contactors, display panels.
9
10 The BMS Mini S has a heat sink to dissipate the heat generated during the balancing of the cells. When used in enclosed enclosures, heat must be removed from the sink, otherwise it may damage the device.
11
12 Overall and mounting dimensions of the BMS Mini S are shown on figures below.
13
14
15 [[image:1733740731815-730.png||data-xwiki-image-style-alignment="center" height="454" width="516"]]
16
17 [[image:1733740731820-300.png||data-xwiki-image-style-alignment="center" height="172" width="453"]]
18
19 |**Parameter**|**Value **
20 |Overall dimensions (length × width × height), mm|124.5 × 117 × 17
21 |Mounting dimensions (length × width), mm|115 × 111
22 |Mounting holes|M3
23
24 == Headers ==
25
26 There are names and locations of the BMS Mini S headers on figure below.
27
28 [[image:1733740765989-365.png||data-xwiki-image-style-alignment="center" height="423" width="526"]]
29
30 === Х1 – header for contactors. ===
31
32 [[image:1733738660904-795.jpeg||data-xwiki-image-style-alignment="center" height="96" width="316"]]
33
34 |**Pin**|**Name**|**Description**
35 |**1**|**-**|-
36 |**2**|**+12V**|Supply voltage from the internal 12V DC/DC converter
37 |**3**|**GND**|Ground
38 |**4**|**+12V**|Supply voltage from the internal 12V DC/DC converter
39 |**5**|**GND**|Ground
40 |**6**|**+12V**|Supply voltage from the internal 12V DC/DC converter
41 |**7**|**GND**|Ground
42 |**8**|**+12V**|Supply voltage from the internal 12V DC/DC converter
43 |**9**|**GND**|Ground
44 |**10**|**-**|-
45 |**11**|**FB1**|Feedback signal from contactor 1
46 |**12**|**OUT1**|Contactor control 1 (low side switch), 100V, max 5A
47 |**13**|**FB2**|Feedback signal from contactor 2
48 |**14**|**OUT2**|Contactor control 2 (low side switch), 100V, max 5A
49 |**15**|**FB3**|Feedback signal from contactor 3
50 |**16**|**OUT3**|Contactor control 3 (low side switch), 100V, max 5A
51 |**17**|**FB4**|Feedback signal from contactor 4
52 |**18**|**OUT4**|Contactor control 4 (low side switch), 100V, max 5A
53
54 (% class="box warningmessage" %)
55 (((
56 **ATTENTION!!!**
57 The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor:
58 [[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
59 )))
60
61 === X2 – mini-USB connector. ===
62
63 Mini-USB connector is used for configuring the BMS via ElectricDeviceMonitor.
64
65 === X3 – header for discrete inputs and outputs signals.[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]] ===
66
67 |**Pin**|**Name**|**Description**
68 |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V)
69 |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V)
70 |**3**|**DIN3**|Discrete input 3 “dry contact” (+5V)
71 |**4**|**DIN4**|Discrete input 4 “dry contact” (+5V)
72 |**5**|**DOUT1**|Discrete output 1 (+5V, 20mA)
73 |**6**|**DOUT2**|Discrete output 2 (+5V, 20mA)
74 |**7**|**DOUT3**|Discrete output 3 (+5V, 20mA)
75 |**8**|**DOUT4**|Discrete output 4 (+5V, 20mA)
76 |**9**|**GND**|Discrete input 1 “dry contact” (ground)
77 |**10**|**GND**|Discrete input 2 “dry contact” (ground)
78 |**11**|**GND**|Discrete input 3 “dry contact” (ground)
79 |**12**|**GND**|Discrete input 4 “dry contact” (ground)
80 |**13**|**GND**|Discrete output 1 (ground)
81 |**14**|**GND**|Discrete output 2 (ground)
82 |**15**|**GND**|Discrete output 3 (ground)
83 |**16**|**GND**|Discrete output 4 (ground)
84
85 === Х4 – header for САN and RS485 interfaces. ===
86
87 [[image:1733738660905-974.jpeg||data-xwiki-image-style-alignment="center" height="70" width="97"]]
88
89 |**Pin**|**Name**|**Description**
90 |**1**|**RS485_B**|RS485 line B
91 |**2**|**+5V**|Isolated supply voltage 5V, max 400mA
92 |**3**|**CAN_L**|CAN-L line of the CAN bus
93 |**4**|**RS485_A**|RS485 line A
94 |**5**|**GND**|Isolated ground
95 |**6**|**CAN_H**|CAN-H line of the CAN bus
96
97 === Х5 – header for ON/OFF button.[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]] ===
98
99 |**Pin**|**Name**|**Description**
100 |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V)
101 |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground)
102
103 === X6 – header for cells temperature sensors. ===
104
105 [[image:1733738660906-697.png||data-xwiki-image-style-alignment="center" height="91" width="190"]]
106
107 |**Pin**|**Name**|**Description**
108 |**1**|**TEMPG1**|Ground of the thermistor 1
109 |**2**|**TEMPG2**|Ground of the thermistor 2
110 |**3**|**TEMPG3**|Ground of the thermistor 3
111 |**4**|**TEMPG4**|Ground of the thermistor 4
112 |**5**|**TEMPG5**|Ground of the thermistor 5
113 |**6**|**TEMPG6**|Ground of the thermistor 6
114 |**7**|**TEMP1**|Signal from the thermistor 1
115 |**8**|**TEMP2**|Signal from the thermistor 2
116 |**9**|**TEMP3**|Signal from the thermistor 3
117 |**10**|**TEMP4**|Signal from the thermistor 4
118 |**11**|**TEMP5**|Signal from the thermistor 5
119 |**12**|**TEMP6**|Signal from the thermistor 6
120
121 === X7 - header for current sensor.[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] ===
122
123 |**Pin**|**Name**|**Description**
124 |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA
125 |**2**|**GND**|Ground
126 |**3**|**Vcs**|ADC input (current sensor output)
127 |**4**|**Vref**|Auxiliary ADC input (current sensor reference signal)
128
129 === Х8 – header for battery cells ===
130
131 [[image:1733740846257-439.png||data-xwiki-image-style-alignment="center" height="89" width="219"]]
132
133 |**Pin**|**Name**|**Description**
134 |**1**|**C0**|Minus of the cell stack (for measuring purposes only)
135 |**2**|**C2**|Cell 2
136 |**3**|**C4**|Cell 4
137 |**4**|**C6**|Cell 6
138 |**5**|**C8**|Cell 8
139 |**6**|**C10**|Cell 10
140 |**7**|**C12**|Cell 12 (maximum potential of the cell stack, for measuring purposes only)
141 |**8**|**NC**|Not connected
142 |**9**|**C1**|Cell 1 (minimum potential with respect to C0)
143 |**10**|**C3**|Cell 3
144 |**11**|**C5**|Cell 5
145 |**12**|**C7**|Cell 7
146 |**13**|**C9**|Cell 9
147 |**14**|**C11**|Cell 11
148
149 === Х9 – header to power the device ===
150
151 [[image:1733738660910-242.png||data-xwiki-image-style-alignment="center" height="61" width="78"]]
152
153 |**Pin**|**Name**|**Description**
154 |**1**|**VBAT+**|Supply voltage for BMS Mini S
155 |**2**|**VBAT-**|BMS Mini S power ground
156
157 (% class="box warningmessage" %)
158 (((
159 **Attention! **The BMS Mini S device is **galvanically connected** to the battery (the minus of the battery is the device ground). In view of this, when a BMS Wi-Fi or BMS GSM module is connected to the device, the antenna braid will also be galvanically connected to the battery (connected to the battery negative). It is recommended to** isolate the antenna cable from the battery case **to prevent negative potential from appearing on the case.
160 )))
161
162 === J1 – jumper for switching CAN bus terminal resistor ===
163
164 To connect the terminal resistor between the** CAN_H** and **CAN_L** lines, install the jumper J1 according to the following figure:
165
166 [[image:1733738660910-372.png||data-xwiki-image-style-alignment="center" height="85" width="162"]]
167
168 === J2 – jumper for switching RS-485 terminal resistor ===
169
170 To connect the terminal resistor between the** RS485_A** and **RS485_B** lines, install the jumper J1 according to the following figure:
171
172 [[image:1733738660910-372.png||data-xwiki-image-style-alignment="center" height="85" width="162"]]
173
174 == Connection procedure ==
175
176 === Connecting battery cells ===
177
178 To connect battery cells, follow figure below. Incorrect connection of the cells can damage the BMS Mini.
179
180 Begin the connection with the negative line of the battery: the “C0“ is connected to the “B-“, then the first cell (C1) is connected, then the second (С2), etc. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the most potential.
181
182 [[image:1733740980966-804.png||data-xwiki-image-style-alignment="center" height="471" width="721"]]
183
184 (% class="box warningmessage" %)
185 (((
186 **Attention!**
187 Connect the battery according to the diagram, otherwise the device may be damaged.
188 )))
189
190 === Connecting thermistors ===
191
192 Thermistors should be fastened to the cells, excluding short circuits to the cell terminals (for example, isolate thermistors with heat shrink).
193