Last modified by Admin on 2025/03/18 12:50

From version 8.1
edited by Admin
on 2025/02/20 13:15
Change comment: There is no comment for this version
To version 3.1
edited by Admin
on 2024/12/09 10:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Mini S.WebHome
1 +drafts.BMS Mini S.WebHome
Content
... ... @@ -16,11 +16,14 @@
16 16  
17 17  [[image:1733740731820-300.png||data-xwiki-image-style-alignment="center" height="172" width="453"]]
18 18  
19 -|**Parameter**|**Value **
20 -|Overall dimensions (length × width × height), mm|124.5 × 117 × 17
19 +|(((
20 +**Parameter**
21 +)))|**Value **
22 +|(((
23 +Overall dimensions (length × width × height), mm
24 +)))|124.5 × 117 × 17
21 21  |Mounting dimensions (length × width), mm|115 × 111
22 22  |Mounting holes|M3
23 -|Headers X1, X3-X9 type|Molex series Micro-Fit
24 24  
25 25  == Headers ==
26 26  
... ... @@ -28,10 +28,8 @@
28 28  
29 29  [[image:1733740765989-365.png||data-xwiki-image-style-alignment="center" height="423" width="526"]]
30 30  
31 -=== X1 – header for contactors ===
34 +=== Х1 – header for contactors. ===
32 32  
33 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030
34 -
35 35  [[image:1733738660904-795.jpeg||data-xwiki-image-style-alignment="center" height="96" width="316"]]
36 36  
37 37  |**Pin**|**Name**|**Description**
... ... @@ -58,20 +58,16 @@
58 58  (((
59 59  **ATTENTION!!!**
60 60  The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor:
61 -[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
62 62  )))
63 63  
64 +[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center"]]
65 +
64 64  === X2 – mini-USB connector. ===
65 65  
66 -Mini-USB connector is used for configuring the BMS via ElectricDeviceMonitor.
68 +Mini0USB connector is used for configuring the BMS via ElectricDeviceMonito
67 67  
68 -=== X3 – header for discrete inputs and outputs signals ===
70 +=== X3 – header for discrete inputs and outputs signals.[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]] ===
69 69  
70 -Receptacle Housing: Molex 430251600. Terminals: Molex 43030
71 -
72 -(% class="wikigeneratedid" %)
73 -[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]]
74 -
75 75  |**Pin**|**Name**|**Description**
76 76  |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V)
77 77  |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V)
... ... @@ -90,10 +90,8 @@
90 90  |**15**|**GND**|Discrete output 3 (ground)
91 91  |**16**|**GND**|Discrete output 4 (ground)
92 92  
93 -=== Х4 – header for САN and RS485 interfaces ===
90 +=== Х4 – header for САN and RS485 interfaces. ===
94 94  
95 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030
96 -
97 97  [[image:1733738660905-974.jpeg||data-xwiki-image-style-alignment="center" height="70" width="97"]]
98 98  
99 99  |**Pin**|**Name**|**Description**
... ... @@ -104,22 +104,14 @@
104 104  |**5**|**GND**|Isolated ground
105 105  |**6**|**CAN_H**|CAN-H line of the CAN bus
106 106  
107 -=== Х5 – header for ON/OFF button ===
102 +=== Х5 – header for ON/OFF button.[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]] ===
108 108  
109 -(% class="wikigeneratedid" %)
110 -Receptacle Housing: Molex 430250200. Terminals: Molex 43030
111 -
112 -(% class="wikigeneratedid" %)
113 -[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
114 -
115 115  |**Pin**|**Name**|**Description**
116 116  |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V)
117 117  |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground)
118 118  
119 -=== X6 – header for cells temperature sensors ===
108 +=== X6 – header for cells temperature sensors. ===
120 120  
121 -Receptacle Housing: Molex 430251200. Terminals: Molex 43030
122 -
123 123  [[image:1733738660906-697.png||data-xwiki-image-style-alignment="center" height="91" width="190"]]
124 124  
125 125  |**Pin**|**Name**|**Description**
... ... @@ -136,21 +136,8 @@
136 136  |**11**|**TEMP5**|Signal from the thermistor 5
137 137  |**12**|**TEMP6**|Signal from the thermistor 6
138 138  
139 -=== X7 - header for current sensor ===
126 +=== X7 - header for current sensor.[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] ===
140 140  
141 -(% class="wikigeneratedid" %)
142 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
143 -
144 -
145 -
146 -
147 -
148 -
149 -
150 -
151 -(% class="wikigeneratedid" %)
152 -[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
153 -
154 154  |**Pin**|**Name**|**Description**
155 155  |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA
156 156  |**2**|**GND**|Ground
... ... @@ -159,8 +159,6 @@
159 159  
160 160  === Х8 – header for battery cells ===
161 161  
162 -Receptacle Housing: Molex 430251400. Terminals: Molex 43030
163 -
164 164  [[image:1733740846257-439.png||data-xwiki-image-style-alignment="center" height="89" width="219"]]
165 165  
166 166  |**Pin**|**Name**|**Description**
... ... @@ -181,8 +181,6 @@
181 181  
182 182  === Х9 – header to power the device ===
183 183  
184 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
185 -
186 186  [[image:1733738660910-242.png||data-xwiki-image-style-alignment="center" height="61" width="78"]]
187 187  
188 188  |**Pin**|**Name**|**Description**
... ... @@ -210,6 +210,7 @@
210 210  
211 211  === Connecting battery cells ===
212 212  
183 +
213 213  To connect battery cells, follow figure below. Incorrect connection of the cells can damage the BMS Mini.
214 214  
215 215  Begin the connection with the negative line of the battery: the “C0“ is connected to the “B-“, then the first cell (C1) is connected, then the second (С2), etc. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the most potential.