Last modified by Admin on 2025/03/18 12:50

From version 8.1
edited by Admin
on 2025/02/20 13:15
Change comment: There is no comment for this version
To version 13.1
edited by Admin
on 2025/03/18 12:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,24 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 +== Safety rules ==
5 +
6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor** able to break the load and charge circuits must be connected to the BMS.
7 +
8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 +
10 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series.
11 +
12 +(% class="box errormessage" %)
13 +(((
14 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
15 +)))
16 +
17 +(% class="box errormessage" %)
18 +(((
19 +The system is not designed to operate with batteries whose total voltage exceeds 60 V.
20 +)))
21 +
4 4  == Installation procedure ==
5 5  
6 6  The mounting area of the BMS Mini S must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Mini S is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
... ... @@ -20,7 +20,6 @@
20 20  |Overall dimensions (length × width × height), mm|124.5 × 117 × 17
21 21  |Mounting dimensions (length × width), mm|115 × 111
22 22  |Mounting holes|M3
23 -|Headers X1, X3-X9 type|Molex series Micro-Fit
24 24  
25 25  == Headers ==
26 26  
... ... @@ -46,13 +46,13 @@
46 46  |**9**|**GND**|Ground
47 47  |**10**|**-**|-
48 48  |**11**|**FB1**|Feedback signal from contactor 1
49 -|**12**|**OUT1**|Contactor control 1 (low side switch), 100V, max 5A
66 +|**12**|**OUT1**|Contactor control 1 (low side switch), 60V, max 5A
50 50  |**13**|**FB2**|Feedback signal from contactor 2
51 -|**14**|**OUT2**|Contactor control 2 (low side switch), 100V, max 5A
68 +|**14**|**OUT2**|Contactor control 2 (low side switch), 60V, max 5A
52 52  |**15**|**FB3**|Feedback signal from contactor 3
53 -|**16**|**OUT3**|Contactor control 3 (low side switch), 100V, max 5A
70 +|**16**|**OUT3**|Contactor control 3 (low side switch), 60V, max 5A
54 54  |**17**|**FB4**|Feedback signal from contactor 4
55 -|**18**|**OUT4**|Contactor control 4 (low side switch), 100V, max 5A
72 +|**18**|**OUT4**|Contactor control 4 (low side switch), 60V, max 5A
56 56  
57 57  (% class="box warningmessage" %)
58 58  (((
... ... @@ -141,13 +141,6 @@
141 141  (% class="wikigeneratedid" %)
142 142  Receptacle Housing: Molex 430250400. Terminals: Molex 43030
143 143  
144 -
145 -
146 -
147 -
148 -
149 -
150 -
151 151  (% class="wikigeneratedid" %)
152 152  [[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
153 153