Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,24 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 + 12 +(% class="box warningmessage" %) 13 +((( 14 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 15 +))) 16 + 17 +(% class="box errormessage" %) 18 +((( 19 +**The system is not designed to operate with batteries whose total voltage exceeds 60 V.** 20 +))) 21 + 4 4 == Installation procedure == 5 5 6 6 The mounting area of the BMS Mini S must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Mini S is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation. ... ... @@ -20,7 +20,6 @@ 20 20 |Overall dimensions (length × width × height), mm|124.5 × 117 × 17 21 21 |Mounting dimensions (length × width), mm|115 × 111 22 22 |Mounting holes|M3 23 -|Headers X1, X3-X9 type|Molex series Micro-Fit 24 24 25 25 == Headers == 26 26 ... ... @@ -46,13 +46,13 @@ 46 46 |**9**|**GND**|Ground 47 47 |**10**|**-**|- 48 48 |**11**|**FB1**|Feedback signal from contactor 1 49 -|**12**|**OUT1**|Contactor control 1 (low side switch), 100V, max 5A66 +|**12**|**OUT1**|Contactor control 1 (low side switch), 60V, max 5A 50 50 |**13**|**FB2**|Feedback signal from contactor 2 51 -|**14**|**OUT2**|Contactor control 2 (low side switch), 100V, max 5A68 +|**14**|**OUT2**|Contactor control 2 (low side switch), 60V, max 5A 52 52 |**15**|**FB3**|Feedback signal from contactor 3 53 -|**16**|**OUT3**|Contactor control 3 (low side switch), 100V, max 5A70 +|**16**|**OUT3**|Contactor control 3 (low side switch), 60V, max 5A 54 54 |**17**|**FB4**|Feedback signal from contactor 4 55 -|**18**|**OUT4**|Contactor control 4 (low side switch), 100V, max 5A72 +|**18**|**OUT4**|Contactor control 4 (low side switch), 60V, max 5A 56 56 57 57 (% class="box warningmessage" %) 58 58 ((( ... ... @@ -141,13 +141,6 @@ 141 141 (% class="wikigeneratedid" %) 142 142 Receptacle Housing: Molex 430250400. Terminals: Molex 43030 143 143 144 - 145 - 146 - 147 - 148 - 149 - 150 - 151 151 (% class="wikigeneratedid" %) 152 152 [[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] 153 153