Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,24 @@ 1 1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 2 = Installation and connection = 3 3 4 +== Safety rules == 5 + 6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS. 7 + 8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured. 9 + 10 +It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series. 11 + 12 +(% class="box warningmessage" %) 13 +((( 14 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery. 15 +))) 16 + 17 +(% class="box errormessage" %) 18 +((( 19 +**The system is not designed to operate with batteries whose total voltage exceeds 60 V.** 20 +))) 21 + 4 4 == Installation procedure == 5 5 6 6 The mounting area of the BMS Mini S must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Mini S is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation. ... ... @@ -27,8 +27,10 @@ 27 27 28 28 [[image:1733740765989-365.png||data-xwiki-image-style-alignment="center" height="423" width="526"]] 29 29 30 -=== X1 – header for contactors .===48 +=== X1 – header for contactors === 31 31 50 +Receptacle Housing: Molex 430251800. Terminals: Molex 43030 51 + 32 32 [[image:1733738660904-795.jpeg||data-xwiki-image-style-alignment="center" height="96" width="316"]] 33 33 34 34 |**Pin**|**Name**|**Description** ... ... @@ -43,13 +43,13 @@ 43 43 |**9**|**GND**|Ground 44 44 |**10**|**-**|- 45 45 |**11**|**FB1**|Feedback signal from contactor 1 46 -|**12**|**OUT1**|Contactor control 1 (low side switch), 100V, max 5A66 +|**12**|**OUT1**|Contactor control 1 (low side switch), 60V, max 5A 47 47 |**13**|**FB2**|Feedback signal from contactor 2 48 -|**14**|**OUT2**|Contactor control 2 (low side switch), 100V, max 5A68 +|**14**|**OUT2**|Contactor control 2 (low side switch), 60V, max 5A 49 49 |**15**|**FB3**|Feedback signal from contactor 3 50 -|**16**|**OUT3**|Contactor control 3 (low side switch), 100V, max 5A70 +|**16**|**OUT3**|Contactor control 3 (low side switch), 60V, max 5A 51 51 |**17**|**FB4**|Feedback signal from contactor 4 52 -|**18**|**OUT4**|Contactor control 4 (low side switch), 100V, max 5A72 +|**18**|**OUT4**|Contactor control 4 (low side switch), 60V, max 5A 53 53 54 54 (% class="box warningmessage" %) 55 55 ((( ... ... @@ -62,8 +62,13 @@ 62 62 63 63 Mini-USB connector is used for configuring the BMS via ElectricDeviceMonitor. 64 64 65 -=== X3 – header for discrete inputs and outputs signals .[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center"height="90" width="283"]]===85 +=== X3 – header for discrete inputs and outputs signals === 66 66 87 +Receptacle Housing: Molex 430251600. Terminals: Molex 43030 88 + 89 +(% class="wikigeneratedid" %) 90 +[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]] 91 + 67 67 |**Pin**|**Name**|**Description** 68 68 |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V) 69 69 |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V) ... ... @@ -82,8 +82,10 @@ 82 82 |**15**|**GND**|Discrete output 3 (ground) 83 83 |**16**|**GND**|Discrete output 4 (ground) 84 84 85 -=== Х4 – header for САN and RS485 interfaces .===110 +=== Х4 – header for САN and RS485 interfaces === 86 86 112 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 113 + 87 87 [[image:1733738660905-974.jpeg||data-xwiki-image-style-alignment="center" height="70" width="97"]] 88 88 89 89 |**Pin**|**Name**|**Description** ... ... @@ -94,14 +94,22 @@ 94 94 |**5**|**GND**|Isolated ground 95 95 |**6**|**CAN_H**|CAN-H line of the CAN bus 96 96 97 -=== Х5 – header for ON/OFF button .[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center"height="70" width="41"]]===124 +=== Х5 – header for ON/OFF button === 98 98 126 +(% class="wikigeneratedid" %) 127 +Receptacle Housing: Molex 430250200. Terminals: Molex 43030 128 + 129 +(% class="wikigeneratedid" %) 130 +[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]] 131 + 99 99 |**Pin**|**Name**|**Description** 100 100 |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V) 101 101 |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground) 102 102 103 -=== X6 – header for cells temperature sensors .===136 +=== X6 – header for cells temperature sensors === 104 104 138 +Receptacle Housing: Molex 430251200. Terminals: Molex 43030 139 + 105 105 [[image:1733738660906-697.png||data-xwiki-image-style-alignment="center" height="91" width="190"]] 106 106 107 107 |**Pin**|**Name**|**Description** ... ... @@ -118,8 +118,14 @@ 118 118 |**11**|**TEMP5**|Signal from the thermistor 5 119 119 |**12**|**TEMP6**|Signal from the thermistor 6 120 120 121 -=== X7 - header for current sensor .[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center"height="79" width="71"]]===156 +=== X7 - header for current sensor === 122 122 158 +(% class="wikigeneratedid" %) 159 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 160 + 161 +(% class="wikigeneratedid" %) 162 +[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]] 163 + 123 123 |**Pin**|**Name**|**Description** 124 124 |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA 125 125 |**2**|**GND**|Ground ... ... @@ -128,6 +128,8 @@ 128 128 129 129 === Х8 – header for battery cells === 130 130 172 +Receptacle Housing: Molex 430251400. Terminals: Molex 43030 173 + 131 131 [[image:1733740846257-439.png||data-xwiki-image-style-alignment="center" height="89" width="219"]] 132 132 133 133 |**Pin**|**Name**|**Description** ... ... @@ -148,6 +148,8 @@ 148 148 149 149 === Х9 – header to power the device === 150 150 194 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 195 + 151 151 [[image:1733738660910-242.png||data-xwiki-image-style-alignment="center" height="61" width="78"]] 152 152 153 153 |**Pin**|**Name**|**Description**