1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 -== Safety rules ==
5 -
6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS.
7 -
8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 -
10 -It is not recommended to use the system in batteries formed by several series of cells connected in parallel. To increase capacity, it is recommended to connect several cells in parallel groups, and then connect the groups in series.
11 -
12 -(% class="box warningmessage" %)
13 -(((
14 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
15 -)))
16 -
17 -(% class="box errormessage" %)
18 -(((
19 -**The system is not designed to operate with batteries whose total voltage exceeds 60 V.**
20 -)))
21 -
22 22  == Installation procedure ==
23 23  
24 -The mounting area of the BMS Mini S must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Mini S is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
6 +The mounting area of the BMS Mini must be protected from mechanical particles (dust, dirt, large objects) and water. The BMS Mini is recommended to be placed close to the cells it controls, but away from high current circuits to reduce interference to measuring circuits and increase overall reliability of installation.
25 25  
26 26  The installation site must provide convenient access for subsequent connection to the device’s headers for connecting other system elements: a current sensor, contactors, display panels.
27 27  
28 -The BMS Mini S has a heat sink to dissipate the heat generated during the balancing of the cells. When used in enclosed enclosures, heat must be removed from the sink, otherwise it may damage the device.
10 +The BMS Mini has a heat sink to dissipate the heat generated during the balancing of the cells. When used in enclosed enclosures, heat must be removed from the sink, otherwise it may damage the device.
29 29  
30 -Overall and mounting dimensions of the BMS Mini S are shown on figures below.
12 +Overall and mounting dimensions of the BMS Mini are shown on figures below.
31 31  
14 +[[image:1733738313780-948.png||data-xwiki-image-style-alignment="center" height="442" width="547"]]
32 32  
33 -[[image:1733740731815-730.png||data-xwiki-image-style-alignment="center" height="454" width="516"]]
16 +[[image:1733738313786-252.png||data-xwiki-image-style-alignment="center" height="150" width="545"]]
34 34  
35 -[[image:1733740731820-300.png||data-xwiki-image-style-alignment="center" height="172" width="453"]]
36 -
37 -|**Parameter**|**Value **
38 -|Overall dimensions (length × width × height), mm|124.5 × 117 × 17
39 -|Mounting dimensions (length × width), mm|115 × 111
18 +|(((
19 +**Parameter**
20 +)))|**Value **
21 +|(((
22 +Overall dimensions (length × width × height), mm
23 +)))|139.5 × 117 × 17
24 +|Mounting dimensions (length × width), mm|130 × 111
40 40  |Mounting holes|M3
41 41  
42 42  == Headers ==
43 43  
44 -There are names and locations of the BMS Mini S headers on figure below.
29 +There are names and locations of the BMS Mini headers on figure below.
45 45  
46 -[[image:1733740765989-365.png||data-xwiki-image-style-alignment="center" height="423" width="526"]]
31 +[[image:1733738660900-622.png||data-xwiki-image-style-alignment="center" height="379" width="508"]]
47 47  
48 -=== X1 – header for contactors ===
33 +=== Х1 – header for contactors. ===
49 49  
50 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030
51 -
52 52  [[image:1733738660904-795.jpeg||data-xwiki-image-style-alignment="center" height="96" width="316"]]
53 53  
54 54  |**Pin**|**Name**|**Description**
... ... @@ -63,32 +63,30 @@
63 63  |**9**|**GND**|Ground
64 64  |**10**|**-**|-
65 65  |**11**|**FB1**|Feedback signal from contactor 1
66 -|**12**|**OUT1**|Contactor control 1 (low side switch), 60V, max 5A
49 +|**12**|**OUT1**|Contactor control 1 (low side switch), 100V, max 5A
67 67  |**13**|**FB2**|Feedback signal from contactor 2
68 -|**14**|**OUT2**|Contactor control 2 (low side switch), 60V, max 5A
51 +|**14**|**OUT2**|Contactor control 2 (low side switch), 100V, max 5A
69 69  |**15**|**FB3**|Feedback signal from contactor 3
70 -|**16**|**OUT3**|Contactor control 3 (low side switch), 60V, max 5A
53 +|**16**|**OUT3**|Contactor control 3 (low side switch), 100V, max 5A
71 71  |**17**|**FB4**|Feedback signal from contactor 4
72 -|**18**|**OUT4**|Contactor control 4 (low side switch), 60V, max 5A
55 +|**18**|**OUT4**|Contactor control 4 (low side switch), 100V, max 5A
73 73  
74 74  (% class="box warningmessage" %)
75 75  (((
76 76  **ATTENTION!!!**
77 77  The load should be connected to +12V and OUTx pins. The feedback signal should be connected to FBx and GND pins. Below is an example of connecting the BMS to a contactor:
78 -[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
79 79  )))
80 80  
63 +[[image:1733738760833-185.png||data-xwiki-image-style-alignment="center"]]
64 +
81 81  === X2 – mini-USB connector. ===
82 82  
83 -Mini-USB connector is used for configuring the BMS via ElectricDeviceMonitor.
67 +Mini0USB connector is used for configuring the BMS via ElectricDeviceMonito
84 84  
85 -=== X3 – header for discrete inputs and outputs signals ===
69 +=== X3 – header for discrete inputs and outputs signals. ===
86 86  
87 -Receptacle Housing: Molex 430251600. Terminals: Molex 43030
71 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image003.emz]][[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]]
88 88  
89 -(% class="wikigeneratedid" %)
90 -[[image:1733738860923-996.png||data-xwiki-image-style-alignment="center" height="90" width="283"]]
91 -
92 92  |**Pin**|**Name**|**Description**
93 93  |**1**|**DIN1**|Discrete input 1 “dry contact” (+5V)
94 94  |**2**|**DIN2**|Discrete input 2 “dry contact” (+5V)
... ... @@ -107,10 +107,8 @@
107 107  |**15**|**GND**|Discrete output 3 (ground)
108 108  |**16**|**GND**|Discrete output 4 (ground)
109 109  
110 -=== Х4 – header for САN and RS485 interfaces ===
91 +=== Х4 – header for САN and RS485 interfaces. ===
111 111  
112 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030
113 -
114 114  [[image:1733738660905-974.jpeg||data-xwiki-image-style-alignment="center" height="70" width="97"]]
115 115  
116 116  |**Pin**|**Name**|**Description**
... ... @@ -121,22 +121,16 @@
121 121  |**5**|**GND**|Isolated ground
122 122  |**6**|**CAN_H**|CAN-H line of the CAN bus
123 123  
124 -=== Х5 – header for ON/OFF button ===
103 +=== Х5 – header for ON/OFF button. ===
125 125  
126 -(% class="wikigeneratedid" %)
127 -Receptacle Housing: Molex 430250200. Terminals: Molex 43030
105 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image005.emz]][[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
128 128  
129 -(% class="wikigeneratedid" %)
130 -[[image:1733739076878-324.png||data-xwiki-image-style-alignment="center" height="70" width="41"]]
131 -
132 132  |**Pin**|**Name**|**Description**
133 133  |**1**|**BTN**|Signal to turn on/off the BMS (“dry contact”, +3.3V)
134 134  |**2**|**GND**|Signal to turn on/off the BMS (“dry contact”, ground)
135 135  
136 -=== X6 – header for cells temperature sensors ===
111 +=== X6 – header for cells temperature sensors. ===
137 137  
138 -Receptacle Housing: Molex 430251200. Terminals: Molex 43030
139 -
140 140  [[image:1733738660906-697.png||data-xwiki-image-style-alignment="center" height="91" width="190"]]
141 141  
142 142  |**Pin**|**Name**|**Description**
... ... @@ -153,14 +153,10 @@
153 153  |**11**|**TEMP5**|Signal from the thermistor 5
154 154  |**12**|**TEMP6**|Signal from the thermistor 6
155 155  
156 -=== X7 - header for current sensor ===
129 +=== X7 - header for current sensor. ===
157 157  
158 -(% class="wikigeneratedid" %)
159 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
131 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image007.emz]][[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
160 160  
161 -(% class="wikigeneratedid" %)
162 -[[image:1733739118831-618.png||data-xwiki-image-style-alignment="center" height="79" width="71"]]
163 -
164 164  |**Pin**|**Name**|**Description**
165 165  |**1**|**+5V**|Supply voltage for a current sensor 5V, max 50 mA
166 166  |**2**|**GND**|Ground
... ... @@ -169,10 +169,8 @@
169 169  
170 170  === Х8 – header for battery cells ===
171 171  
172 -Receptacle Housing: Molex 430251400. Terminals: Molex 43030
141 +[[image:1733738660908-107.jpeg||data-xwiki-image-style-alignment="center" height="83" width="291"]]
173 173  
174 -[[image:1733740846257-439.png||data-xwiki-image-style-alignment="center" height="89" width="219"]]
175 -
176 176  |**Pin**|**Name**|**Description**
177 177  |**1**|**C0**|Minus of the cell stack (for measuring purposes only)
178 178  |**2**|**C2**|Cell 2
... ... @@ -180,24 +180,28 @@
180 180  |**4**|**C6**|Cell 6
181 181  |**5**|**C8**|Cell 8
182 182  |**6**|**C10**|Cell 10
183 -|**7**|**C12**|Cell 12 (maximum potential of the cell stack, for measuring purposes only)
184 -|**8**|**NC**|Not connected
185 -|**9**|**C1**|Cell 1 (minimum potential with respect to C0)
186 -|**10**|**C3**|Cell 3
187 -|**11**|**C5**|Cell 5
188 -|**12**|**C7**|Cell 7
189 -|**13**|**C9**|Cell 9
190 -|**14**|**C11**|Cell 11
150 +|**7**|**C12**|Cell 12
151 +|**8**|**C14**|Cell 14
152 +|**9**|**C16**|Cell 16
153 +|**10**|**C18**|Cell 18 (maximum potential of the cell stack, for measuring purposes only)
154 +|**11**|**NC**|Not connected
155 +|**12**|**C1**|Cell 1 (minimum potential with respect to C0)
156 +|**13**|**C3**|Cell 3
157 +|**14**|**C5**|Cell 5
158 +|**15**|**C7**|Cell 7
159 +|**16**|**C9**|Cell 9
160 +|**17**|**C11**|Cell 11
161 +|**18**|**C13**|Cell 13
162 +|**19**|**C15**|Cell 15
163 +|**20**|**C17**|Cell 17
191 191  
192 192  === Х9 – header to power the device ===
193 193  
194 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
195 -
196 196  [[image:1733738660910-242.png||data-xwiki-image-style-alignment="center" height="61" width="78"]]
197 197  
198 198  |**Pin**|**Name**|**Description**
199 -|**1**|**VBAT+**|Supply voltage for BMS Mini S
200 -|**2**|**VBAT-**|BMS Mini S power ground
170 +|**1**|**VBAT+**|Supply voltage for BMS Mini
171 +|**2**|**VBAT-**|BMS Mini power ground
201 201  
202 202  (% class="box warningmessage" %)
203 203  (((
... ... @@ -220,11 +220,12 @@
220 220  
221 221  === Connecting battery cells ===
222 222  
194 +
223 223  To connect battery cells, follow figure below. Incorrect connection of the cells can damage the BMS Mini.
224 224  
225 225  Begin the connection with the negative line of the battery: the “C0“ is connected to the “B-“, then the first cell (C1) is connected, then the second (С2), etc. If not all inputs of the cells are used, then the remaining inputs are connected to the cell with the most potential.
226 226  
227 -[[image:1733740980966-804.png||data-xwiki-image-style-alignment="center" height="471" width="721"]]
199 +[[image:1733738660912-678.png||data-xwiki-image-style-alignment="center" height="326" width="650"]]
228 228  
229 229  (% class="box warningmessage" %)
230 230  (((
1733740731815-730.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -130.5 KB
Content
1733740731820-300.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content
1733740765989-365.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -105.5 KB
Content
1733740846257-439.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -13.3 KB
Content
1733740980966-804.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -56.5 KB
Content