4.6 External equipment
Monitoring
External equipment
Information about the status of external equipment is in the "External equipment" section.
BKM controller
Information about the status of communication with the BKM controller is available in the "External equipment → BKM controller" section:

In this section:
- Charger online – a flag of connection with the charger;
- Vehicle online – a flag of connection with the vehicle controller.
Basic J1939 vehicle
Information about the status of communication with the vehicle according to the Basic J1939 protocol is available in the section "External equipment → Basic J1939 vehicle":

In this section:
- Vehicle online – a flag of connection with the vehicle controller.
Evocargo vehicle
Information about the status of communication with the Evocargo vehicle is available in the section "External equipment → Evocargo vehicle":

In this section:
- Vehicle online – a flag of connection with the vehicle controller;
- Charger online – a flag of connection with the charger;
- Discharge request – a flag to close the main discharging contactor;
- Precharge request – a flag to close the main precharging contactor;
- Charge permission – a flag to permit charging;
- Rejoin ACK – a flag to permit rejoining the battery modules;
- Energy – charger energy meter, Wh;
- Internal temperature – charger internal temperature, °C;
- Connector temperature – charging connector temperature, °C;
- Coulomb – charge transferred by the charger, Ah;
- Output voltage – voltage given out by the charger, V;
- Output current – current given out by the charger, A;
- Charger state:
- Sleep;
- Wakeup;
- Standby;
- Ready to charge;
- Charge;
- Shutdown – disabled (an error occurred);
- Charger signal:
- Warning – a malfunction warning;
- Error – an internal error;
- Enabled;
- Wakeup;
- AC detected;
- Connector locked;
- Pilot signal detected;
- Proximity signal detected – connection of the charger to the charger connector is detected.
ATIB charger
Information about the status of communication with an ATIB charger is available in the "External equipment → ATIB charger" section:

In this section:
- Online – a flag of normal communication with the charger;
- Voltage – voltage measured by the charger, V;
- Current – current measured by the charger, A;
- Status – bitfield with status indicators:
- Charger error;
- High temperature;
- Parameters out of limits;
- Battery is not connected;
- Communication error;
- Thermal derating;
- Precharge.
BMS IMD
Information about the status of communication with BMS IMD is available in the "External equipment → BMD IMD" section:

In this section:
- Online – a flag of normal communication with the IMD;
- Configured – a flag indicating successful device set up;
- Insulation status;
- Internal error;
- Device state;
- Resistance (plus) – measured insulation resistance between positive line and chassis, Ohm;
- Resistance (minus) – measured insulation resistance between negative line and chassis, Ohm.
Pylontech inverter
Information about the status of communication with a Pylontech inverter is available in the "External equipment → Pylontech inverter" section:

In this section:
- Online – a flag of normal communication with the inverter.