Changes for page 3.3 Control
Last modified by Admin on 2025/06/11 15:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -101,8 +101,41 @@ 101 101 102 102 To change the parameters for generating status signals when discharging the battery, select the section “Control → Discharging status”: 103 103 104 -[[image:1740749862820-455.png]] 104 +[[image:1740749862820-455.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="95" width="800"]]In this section: 105 105 106 +* Current corresponding to discharging – a current level to set the "Discharging current present" signal, A; 107 +* Current corresponding to no discharging – a current level to clear the "Discharging current present" signal, A. 108 + 109 +=== Precharge === 110 + 111 +To change the precharge parameters, select the section “Control → Precharge”: 112 + 113 +[[image:1740749922669-238.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="165" width="800"]] 114 + 115 +In this section: 116 + 117 +* Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; 118 +* Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 119 +* Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V; 120 +* Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 121 +* Delay before current measurement – a delay before first current measurement after closing precharge, millisecond; 122 +* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 123 +* Relaxation between attempts – a duration between precharge attempts, millisecond; 124 +* Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor; 125 +* Precharge resistor resistance, Ohm; 126 +* Maximum allowable power dissipated in the resistor, W; 127 +* Delay before setting the "Precharge error" when checking power, millisecond; 128 +* Delay before clearing the "Precharge error", second; 129 +* Lock – a flag to block the error until the device is restarted. 130 + 131 +“Precharge error” generation conditions if any of the following is true: 132 + 133 +* the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts"; 134 +* voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts"; 135 +* power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 136 + 137 +Behavior of contactors at “Precharge error” is configured in corresponding contactor settings! 138 + 106 106 === Charge === 107 107 108 108 The BMS Main X device manages the parallel connection of the battery modules and the connection of the battery to the charging circuit.