... ... @@ -73,36 +73,8 @@
73 73  
74 74  To change the parameters of the main contactor, select the "Control → Main contactor" section:
75 75  
76 -[[image:1740749605680-464.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="800"]]
76 +[[image:1740749605680-464.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="88" width="600"]]
77 77  
78 -In this section:
79 -
80 -* Enable – a flag to enable the main contactor control;
81 -* Algorithm – main contactor control algorithm:
82 -** Always on – contactor is always closed;
83 -** Automatic – contactor closes by internal charge and discharge algorithms;
84 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed, millisecond;
85 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, millisecond;
86 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset;
87 -* Errors to open the main contactor – error flags that cause the contactor to open.
88 -
89 -=== Charging status ===
90 -
91 -To change the parameters for generating status signals when charging the battery, select the section “Control → Charging status”:
92 -
93 -[[image:1740749824773-539.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="104" width="800"]]
94 -
95 -In this section:
96 -
97 -* Current corresponding to charging – a current level to set the "Charging current present" signal, A;
98 -* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A.
99 -
100 -=== Discharging status ===
101 -
102 -To change the parameters for generating status signals when discharging the battery, select the section “Control → Discharging status”:
103 -
104 -[[image:1740749862820-455.png]]
105 -
106 106  === Charge ===
107 107  
108 108  The BMS Main X device manages the parallel connection of the battery modules and the connection of the battery to the charging circuit.