... ... @@ -18,18 +18,26 @@
18 18  
19 19  [[image:1734356322698-182.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="600"]]
20 20  
21 +=== Temperature sensors ===
22 +
23 +Temperature sensors settings are configured in the "Signals → Temperature sensors" section:
24 +
25 +[[image:1740747277464-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="600"]]
26 +
27 +In this section:
28 +
29 +* Type – a type of temperature sensors.
30 +
21 21  === Discrete outputs ===
22 22  
23 -The BMS Main X device has **4 digital outputs**. For each discrete output, its assignment and inversion flag are set.
33 +The BMS Main X device has **4 digital outputs (+5V)**. For each discrete output, its assignment and inversion flag are set.
24 24  
25 25  Assignments of discrete outputs are configured in the "Signals - Output discrete signals - Assignments" section:
26 26  
27 27  [[image:1734356322699-904.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="600"]]
28 28  
29 -The device supports the following digital output assignments:
39 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
30 30  
31 -* No output – output is not used.
32 -
33 33  Inversion flags for discrete outputs are configured in the "Signals - Output discrete signals - Inversion" section:
34 34  
35 35  [[image:1734356322700-310.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="111" width="600"]]
... ... @@ -43,14 +43,8 @@
43 43  
44 44  [[image:1734356322702-918.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="600"]]
45 45  
46 -The device supports the following relay assignments:
54 +A list of available relay assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
47 47  
48 -* No relay – relay is not used;
49 -* Charging – main charging contactor;
50 -* Precharging – main precharging contactor;
51 -* Discharging – main discharging contactor;
52 -* Charging/Discharging – main charging/discharging contactor.
53 -
54 54  Inversion flags for relays are configured in the “Signals – Relays – Inversion” section:
55 55  