Content
... ... @@ -6,14 +6,26 @@
6 6  
7 7  === Discrete inputs ===
8 8  
9 -The BMS Main X device has **4 discrete inputs** of the "dry contact" type. For each discrete input, its assignment and inversion flag are set.
9 +The BMS Main X device has 4 discrete inputs of the "dry contact" type. For each discrete input, its assignment and inversion flag are set.
10 10  
11 11  Assignments of discrete inputs are configured in the "Signals - Input discrete signals - Assignments" section:
12 12  
13 13  [[image:1734356322695-445.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="600"]]
14 14  
15 -A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
15 +The device supports the following discrete inputs assignments:
16 16  
17 +* No input – input is not used;
18 +* Battery cover – a signal from the battery cover;
19 +* Charge request – a request to close the main charging contactor;
20 +* Precharge request – a request to close the main precharging contactor;
21 +* Discharge request – a request to close the main discharging contactor;
22 +* Charging contactor feedback – a feedback signal from the charging contactor;
23 +* Discharging contactor feedback – a feedback signal from the discharging contactor;
24 +* Charging/Discharging contactor feedback – a feedback signal from the charging/discharging contactor;
25 +* Insulation status – a signal from an insulation monitoring device;
26 +* Join to charge – a request to join (connect in parallel) battery modules to charge the battery;
27 +* Join to discharge – a request to join (connect in parallel) battery modules to discharge the battery.
28 +
17 17  Inversion flags for discrete inputs are configured in the "Signals - Input discrete signals - Inversion" section:
18 18  
19 19  [[image:1734356322698-182.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="600"]]
... ... @@ -20,7 +20,7 @@
20 20  
21 21  === Discrete outputs ===
22 22  
23 -The BMS Main X device has **4 digital outputs**. For each discrete output, its assignment and inversion flag are set.
35 +The BMS Main X device has 4 +5V digital outputs. For each discrete output, its assignment and inversion flag are set.
24 24  
25 25  Assignments of discrete outputs are configured in the "Signals - Output discrete signals - Assignments" section:
26 26  
... ... @@ -37,7 +37,7 @@
37 37  
38 38  === Relays ===
39 39  
40 -The BMS Main X device has **3 opto-relays** for controlling main contactors. For each opto-relay, its assignment and inversion flag are set.
52 +The BMS Main X device has 3 opto-relays for controlling main contactors. For each opto-relay, its assignment and inversion flag are set.
41 41  
42 42  Assignments of relays are configured in the "Signals - Relays - Assignments" section:
43 43