Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/04/09 12:33

From version 1.2
edited by Admin
on 2024/12/19 11:15
Change comment: Update document after refactoring.
To version 4.1
edited by Admin
on 2025/02/28 12:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,42 +6,38 @@
6 6  
7 7  === Discrete inputs ===
8 8  
9 -The BMS Main X device has 4 discrete inputs of the "dry contact" type. For each discrete input, its assignment and inversion flag are set.
9 +The BMS Main X device has **4 discrete inputs** of the "dry contact" type. For each discrete input, its assignment and inversion flag are set.
10 10  
11 11  Assignments of discrete inputs are configured in the "Signals - Input discrete signals - Assignments" section:
12 12  
13 13  [[image:1734356322695-445.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="600"]]
14 14  
15 -The device supports the following discrete inputs assignments:
15 +A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
16 16  
17 -* No input – input is not used;
18 -* Battery cover – a signal from the battery cover;
19 -* Charge request – a request to close the main charging contactor;
20 -* Precharge request – a request to close the main precharging contactor;
21 -* Discharge request – a request to close the main discharging contactor;
22 -* Charging contactor feedback – a feedback signal from the charging contactor;
23 -* Discharging contactor feedback – a feedback signal from the discharging contactor;
24 -* Charging/Discharging contactor feedback – a feedback signal from the charging/discharging contactor;
25 -* Insulation status – a signal from an insulation monitoring device;
26 -* Join to charge – a request to join (connect in parallel) battery modules to charge the battery;
27 -* Join to discharge – a request to join (connect in parallel) battery modules to discharge the battery.
28 -
29 29  Inversion flags for discrete inputs are configured in the "Signals - Input discrete signals - Inversion" section:
30 30  
31 31  [[image:1734356322698-182.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="600"]]
32 32  
21 +=== Temperature sensors ===
22 +
23 +Temperature sensors settings are configured in the "Signals → Temperature sensors" section:
24 +
25 +[[image:1740747277464-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="600"]]
26 +
27 +In this section:
28 +
29 +* Type – a type of temperature sensors.
30 +
33 33  === Discrete outputs ===
34 34  
35 -The BMS Main X device has 4 +5V digital outputs. For each discrete output, its assignment and inversion flag are set.
33 +The BMS Main X device has **4 digital outputs**. For each discrete output, its assignment and inversion flag are set.
36 36  
37 37  Assignments of discrete outputs are configured in the "Signals - Output discrete signals - Assignments" section:
38 38  
39 39  [[image:1734356322699-904.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="600"]]
40 40  
41 -The device supports the following digital output assignments:
39 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
42 42  
43 -* No output – output is not used.
44 -
45 45  Inversion flags for discrete outputs are configured in the "Signals - Output discrete signals - Inversion" section:
46 46  
47 47  [[image:1734356322700-310.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="111" width="600"]]
... ... @@ -49,20 +49,14 @@
49 49  
50 50  === Relays ===
51 51  
52 -The BMS Main X device has 3 opto-relays for controlling main contactors. For each opto-relay, its assignment and inversion flag are set.
48 +The BMS Main X device has **3 opto-relays** for controlling main contactors. For each opto-relay, its assignment and inversion flag are set.
53 53  
54 54  Assignments of relays are configured in the "Signals - Relays - Assignments" section:
55 55  
56 56  [[image:1734356322702-918.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="600"]]
57 57  
58 -The device supports the following relay assignments:
54 +A list of available relay assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
59 59  
60 -* No relay – relay is not used;
61 -* Charging – main charging contactor;
62 -* Precharging – main precharging contactor;
63 -* Discharging – main discharging contactor;
64 -* Charging/Discharging – main charging/discharging contactor.
65 -
66 66  Inversion flags for relays are configured in the “Signals – Relays – Inversion” section:
67 67  
68 68  [[image:1734356322702-133.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]]
1740747277464-849.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +18.5 KB
Content