Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main X.WebHome1 +drafts.BMS Main X.WebHome - Content
-
... ... @@ -3,11 +3,11 @@ 3 3 4 4 == Installation == 5 5 6 -The mounting area of the BMS Main X must be protected from mechanical particles (dust, dirt, large objects) and water. 6 +The mounting area of the BMS Main X 2.x must be protected from mechanical particles (dust, dirt, large objects) and water. 7 7 8 8 The installation site must provide convenient access for subsequent connection to the device’s headers for connecting other system elements: contactors, temperature sensors, etc. 9 9 10 -Overall and mounting dimensions of the BMS Main X are shown below.10 +Overall and mounting dimensions of the BMS Main X 2.x are shown in Figures 6 and 7. 11 11 12 12 [[image:1734355103230-973.png||data-xwiki-image-style-alignment="center" height="460" width="450"]] 13 13 [[image:1734355103237-284.png||data-xwiki-image-style-alignment="center" height="207" width="450"]] ... ... @@ -20,7 +20,6 @@ 20 20 )))|105 × 115 × 15 21 21 |Mounting dimensions (length × width), mm|99 × 109 22 22 |Mounting holes|M3 23 -|Headers X1, X3-X8 type|Molex series Micro-Fit 24 24 25 25 == Connection == 26 26 ... ... @@ -32,8 +32,6 @@ 32 32 33 33 === Х1 – header for power supply === 34 34 35 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030 36 - 37 37 [[image:1734355208747-667.png||data-xwiki-image-style-alignment="center"]] 38 38 39 39 |**Pin**|**Name**|**Description** ... ... @@ -44,8 +44,6 @@ 44 44 45 45 === X3 – header for CAN (INT) interface === 46 46 47 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 48 - 49 49 [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 50 50 51 51 |**Pin**|**Name**|**Description** ... ... @@ -56,8 +56,6 @@ 56 56 57 57 === Х4 – header for RS-485 interface === 58 58 59 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 60 - 61 61 [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 62 62 63 63 |**Pin**|**Name**|**Description** ... ... @@ -71,75 +71,3 @@ 71 71 To connect the terminal resistor between the** RS485_A** and **RS485_B** lines, install the jumper J1 according to the following figure: 72 72 73 73 [[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]] 74 - 75 -=== Х5 – header for CAN (EXT) interface === 76 - 77 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 78 - 79 -[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 80 - 81 -|**Pin**|**Name**|**Description** 82 -|**1**|**СAN_EXT_H**|CAN-H line of the external CAN bus (communication with a top-level system) 83 -|**2**|**CAN_EXT_L**|CAN-L line of the external CAN bus (communication with a top-level system) 84 -|**3**|**CAN_EXT_5V**|Isolated 5V power supply for external devices, max 200 mA 85 -|**4**|**CAN_EXT_GND**|Isolated ground 86 - 87 -=== J2 – jumper for switching CAN (EXT) terminal resistor === 88 - 89 -To connect the terminal resistor between the** CAN_EXT_H** and **CAN_EXT_L** lines, install the jumper J2 according to the following figure: 90 - 91 -[[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]] 92 - 93 -=== Х6 – header for sold-state relays === 94 - 95 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030 96 - 97 -[[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]] 98 - 99 -|**Pin**|**Name**|**Description** 100 -|**1**|**NO1**|Normally open contact of the relay 1 101 -|**2**|**NO2**|Normally open contact of the relay 2 102 -|**3**|**NO3**|Normally open contact of the relay 3 103 -|**4**|**COM1**|Common contact of the relay 1 (55V, 2A) 104 -|**5**|**COM2**|Common contact of the relay 2 (55V, 2A) 105 -|**6**|**COM3**|Common contact of the relay 3 (55V, 2A) 106 - 107 -=== X7 – header for discrete inputs/outputs === 108 - 109 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030 110 - 111 -[[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]] 112 - 113 -|**Pin**|**Name**|**Description** 114 -|**1**|**GND**|Discrete input 1 “dry contact” (ground) 115 -|**2**|**GND**|Discrete input 2 “dry contact” (ground) 116 -|**3**|**GND**|Discrete input 3 “dry contact” (ground) 117 -|**4**|**GND**|Discrete input 4 “dry contact” (ground) 118 -|**5**|**-**|- 119 -|**6**|**GND**|Discrete output 1 (ground) 120 -|**7**|**GND**|Discrete output 2 (ground) 121 -|**8**|**GND**|Discrete output 3 (ground) 122 -|**9**|**GND**|Discrete output 4 (ground) 123 -|**10**|**D_IN1**|Discrete input 1 “dry contact” (+5V) 124 -|**11**|**D_IN2**|Discrete input 2 “dry contact” (+5V) 125 -|**12**|**D_IN3**|Discrete input 3 “dry contact” (+5V) 126 -|**13**|**D_IN4**|Discrete input 4 “dry contact” (+5V) 127 -|**14**|**-**|- 128 -|**15**|**D_OUT1**|Discrete output 1 (+5V, 20mA) 129 -|**16**|**D_OUT2**|Discrete output 2 (+5V, 20mA) 130 -|**17**|**D_OUT3**|Discrete output 3 (+5V, 20mA) 131 -|**18**|**D_OUT4**|Discrete output 4 (+5V, 20mA) 132 - 133 -=== Х8 – header for temperature sensors === 134 - 135 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030 136 - 137 -[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 138 - 139 -|**Pin**|**Name**|**Description** 140 -|**1**|**TEMPG1**|Ground of the thermistor 1 141 -|**2**|**TEMPG2**|Ground of the thermistor 2 142 -|**3**|**TEMP1**|Signal from the thermistor 1 143 -|**4**|**TEMP2**|Signal from the thermistor 2 144 - 145 -
- 1734355584041-898.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -12.0 KB - Content
- 1734355584043-416.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.8 KB - Content