Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main X.WebHome1 +Battery management systems.BMS Main X.WebHome - Content
-
... ... @@ -3,11 +3,11 @@ 3 3 4 4 == Installation == 5 5 6 -The mounting area of the BMS Main X 2.xmust be protected from mechanical particles (dust, dirt, large objects) and water.6 +The mounting area of the BMS Main X must be protected from mechanical particles (dust, dirt, large objects) and water. 7 7 8 8 The installation site must provide convenient access for subsequent connection to the device’s headers for connecting other system elements: contactors, temperature sensors, etc. 9 9 10 -Overall and mounting dimensions of the BMS Main X 2.xare shownin Figures 6 and 7.10 +Overall and mounting dimensions of the BMS Main X are shown below. 11 11 12 12 [[image:1734355103230-973.png||data-xwiki-image-style-alignment="center" height="460" width="450"]] 13 13 [[image:1734355103237-284.png||data-xwiki-image-style-alignment="center" height="207" width="450"]] ... ... @@ -20,6 +20,7 @@ 20 20 )))|105 × 115 × 15 21 21 |Mounting dimensions (length × width), mm|99 × 109 22 22 |Mounting holes|M3 23 +|Headers X1, X3-X8 type|Molex series Micro-Fit 23 23 24 24 == Connection == 25 25 ... ... @@ -31,6 +31,8 @@ 31 31 32 32 === Х1 – header for power supply === 33 33 35 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030 36 + 34 34 [[image:1734355208747-667.png||data-xwiki-image-style-alignment="center"]] 35 35 36 36 |**Pin**|**Name**|**Description** ... ... @@ -41,6 +41,8 @@ 41 41 42 42 === X3 – header for CAN (INT) interface === 43 43 47 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 48 + 44 44 [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 45 45 46 46 |**Pin**|**Name**|**Description** ... ... @@ -51,6 +51,8 @@ 51 51 52 52 === Х4 – header for RS-485 interface === 53 53 59 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 60 + 54 54 [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 55 55 56 56 |**Pin**|**Name**|**Description** ... ... @@ -64,3 +64,75 @@ 64 64 To connect the terminal resistor between the** RS485_A** and **RS485_B** lines, install the jumper J1 according to the following figure: 65 65 66 66 [[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]] 74 + 75 +=== Х5 – header for CAN (EXT) interface === 76 + 77 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 78 + 79 +[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 80 + 81 +|**Pin**|**Name**|**Description** 82 +|**1**|**СAN_EXT_H**|CAN-H line of the external CAN bus (communication with a top-level system) 83 +|**2**|**CAN_EXT_L**|CAN-L line of the external CAN bus (communication with a top-level system) 84 +|**3**|**CAN_EXT_5V**|Isolated 5V power supply for external devices, max 200 mA 85 +|**4**|**CAN_EXT_GND**|Isolated ground 86 + 87 +=== J2 – jumper for switching CAN (EXT) terminal resistor === 88 + 89 +To connect the terminal resistor between the** CAN_EXT_H** and **CAN_EXT_L** lines, install the jumper J2 according to the following figure: 90 + 91 +[[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]] 92 + 93 +=== Х6 – header for sold-state relays === 94 + 95 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030 96 + 97 +[[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]] 98 + 99 +|**Pin**|**Name**|**Description** 100 +|**1**|**NO1**|Normally open contact of the relay 1 101 +|**2**|**NO2**|Normally open contact of the relay 2 102 +|**3**|**NO3**|Normally open contact of the relay 3 103 +|**4**|**COM1**|Common contact of the relay 1 (55V, 2A) 104 +|**5**|**COM2**|Common contact of the relay 2 (55V, 2A) 105 +|**6**|**COM3**|Common contact of the relay 3 (55V, 2A) 106 + 107 +=== X7 – header for discrete inputs/outputs === 108 + 109 +Receptacle Housing: Molex 430251800. Terminals: Molex 43030 110 + 111 +[[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]] 112 + 113 +|**Pin**|**Name**|**Description** 114 +|**1**|**GND**|Discrete input 1 “dry contact” (ground) 115 +|**2**|**GND**|Discrete input 2 “dry contact” (ground) 116 +|**3**|**GND**|Discrete input 3 “dry contact” (ground) 117 +|**4**|**GND**|Discrete input 4 “dry contact” (ground) 118 +|**5**|**-**|- 119 +|**6**|**GND**|Discrete output 1 (ground) 120 +|**7**|**GND**|Discrete output 2 (ground) 121 +|**8**|**GND**|Discrete output 3 (ground) 122 +|**9**|**GND**|Discrete output 4 (ground) 123 +|**10**|**D_IN1**|Discrete input 1 “dry contact” (+5V) 124 +|**11**|**D_IN2**|Discrete input 2 “dry contact” (+5V) 125 +|**12**|**D_IN3**|Discrete input 3 “dry contact” (+5V) 126 +|**13**|**D_IN4**|Discrete input 4 “dry contact” (+5V) 127 +|**14**|**-**|- 128 +|**15**|**D_OUT1**|Discrete output 1 (+5V, 20mA) 129 +|**16**|**D_OUT2**|Discrete output 2 (+5V, 20mA) 130 +|**17**|**D_OUT3**|Discrete output 3 (+5V, 20mA) 131 +|**18**|**D_OUT4**|Discrete output 4 (+5V, 20mA) 132 + 133 +=== Х8 – header for temperature sensors === 134 + 135 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030 136 + 137 +[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 138 + 139 +|**Pin**|**Name**|**Description** 140 +|**1**|**TEMPG1**|Ground of the thermistor 1 141 +|**2**|**TEMPG2**|Ground of the thermistor 2 142 +|**3**|**TEMP1**|Signal from the thermistor 1 143 +|**4**|**TEMP2**|Signal from the thermistor 2 144 + 145 +
- 1734355584041-898.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.0 KB - Content
- 1734355584043-416.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.8 KB - Content