61 61  To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section:
62 62  
63 -[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]]
63 +[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]]In this section:
64 64  
65 -In this section:
66 -
67 67  * Enable – a flag to enable communication with the IMD;
68 68  * CAN port – port which is used to communicate with the IMD:
69 69  ** CAN1 (ext);
... ... @@ -74,11 +74,11 @@
74 74  * Alarm threshold – a threshold resistance value to set insulation alarm, Ohm;
75 75  * Warning threshold – a threshold resistance value to set insulation warning, Ohm.
76 76  
77 -=== Unibat vehicle ===
75 +=== Unibat vehicle ===
78 78  
79 79  To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section:
80 80  
81 -[[image:1739294567774-840.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="290" width="600"]]
79 +[[image:1739970298499-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="302" width="600"]]
82 82  
83 83  In this section:
84 84  
... ... @@ -115,8 +115,23 @@
115 115  === ATIB charger ===
116 116  
117 117  To change the parameters of communication with an ATIB Elettronica charger, select the "External equipment → ATIB charger" section:
116 +[[image:1739294769684-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="600"]]
118 118  
119 - [[image:1739294769684-405.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="90" width="600"]]
118 +In this section:
120 120  
120 +* Enable – a flag to enable communication with the charger;
121 +* CAN port – port which is used to communicate with the charger:
122 +** CAN1 (ext);
123 +** CAN2 (int);
124 +* Receive timeout – a timeout for receiving packets from the charger (if there is no data being received from the charger for a given time, the connection loss flag is set), millisecond;
125 +* Output period - a period of sending commands to the charger, millisecond;
126 +* Charging voltage – maximum charging voltage, V;
127 +* Charging current – maximum charging current, A;
128 +* Set “Charger connected” signal if the charger is online – a flag to generate the “Charger connected” signal if connection with the charger is established.
121 121  
130 +(% class="box infomessage" %)
131 +(((
132 +After changing the settings, restart the BMS Main 3X device.