Changes for page 3.5 External equipment
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -30,12 +30,11 @@ 30 30 31 31 Communication parameters via the Basic J1939 protocol are configured in the “External equipment – Basic J1939 vehicle” section: 32 32 33 -[[image:1739294413209-387.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="76" width="600"]] 34 34 35 35 In this section: 36 36 37 37 * Enable – a flag to enable communication using the protocol; 38 -* CAN port – port which is used to communicate with the vehicle:37 +* CAN port – port which is used to communicate with the charger: 39 39 ** CAN1 (ext); 40 40 ** CAN2 (int); 41 41 * BMS message ID – an identifier of the first message of the device in the J1939 network; ... ... @@ -45,37 +45,10 @@ 45 45 46 46 Communication parameters for the Evocargo vehicle are configured in the section "External equipment – Evocargo vehicle": 47 47 48 -[[image:173 9294432727-315.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="600"]]47 +[[image:1734357302172-818.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="89" width="600"]] 49 49 50 50 In this section: 51 51 52 52 * Enable – a flag to enable communication with the Evocargo vehicle; 53 -* CAN port – port which is used to communicate with the vehicle: 54 -** CAN1 (ext); 55 -** CAN2 (int); 56 56 * Minimum voltage – minimum battery voltage, V; 57 57 * Maximum voltage – maximum battery voltage, V. 58 - 59 -=== BMS IMD === 60 - 61 -To change communication parameters with an insulation monitoring device BMS IMD, select the "External equipment → BMD IMD " section: 62 - 63 -[[image:1739294477662-343.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]] 64 - 65 -In this section: 66 - 67 -* Enable – a flag to enable communication with the IMD; 68 -* CAN port – port which is used to communicate with the IMD: 69 -** CAN1 (ext); 70 -** CAN2 (int); 71 -* Node ID – a CANopen address of the BMS IMD device; 72 -* Configure IMD – a flag to override the IMD warning and alarm settings; 73 -* Allow work if battery modules are joined – a flag to allow the BMS IMD to work only if battery modules are joined; 74 -* Alarm threshold – a threshold resistance value to set insulation alarm, Ohm; 75 -* Warning threshold – a threshold resistance value to set insulation warning, Ohm. 76 - 77 -=== Unibat vehicle === 78 - 79 -To change communication parameters with vehicle with Unibat battery installed, select the "External equipment → Unibat vehicle" section: 80 - 81 -[[image:1739294567774-840.png]]
- 1739294567774-840.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -84.0 KB - Content